Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit
- PMID: 20059237
- DOI: 10.1117/1.3275463
Real-time display on Fourier domain optical coherence tomography system using a graphics processing unit
Abstract
Fourier domain optical coherence tomography (FD-OCT) requires resampling of spectrally resolved depth information from wavelength to wave number, and the subsequent application of the inverse Fourier transform. The display rates of OCT images are much slower than the image acquisition rates due to processing speed limitations on most computers. We demonstrate a real-time display of processed OCT images using a linear-in-wave-number (linear-k) spectrometer and a graphics processing unit (GPU). We use the linear-k spectrometer with the combination of a diffractive grating with 1200 lines/mm and a F2 equilateral prism in the 840-nm spectral region to avoid calculating the resampling process. The calculations of the fast Fourier transform (FFT) are accelerated by the GPU with many stream processors, which realizes highly parallel processing. A display rate of 27.9 frames/sec for processed images (2048 FFT size x 1000 lateral A-scans) is achieved in our OCT system using a line scan CCD camera operated at 27.9 kHz.
Similar articles
-
Real-time resampling in Fourier domain optical coherence tomography using a graphics processing unit.J Biomed Opt. 2010 May-Jun;15(3):030511. doi: 10.1117/1.3437078. J Biomed Opt. 2010. PMID: 20614994
-
Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units.Appl Opt. 2010 Sep 1;49(25):4756-62. doi: 10.1364/AO.49.004756. Appl Opt. 2010. PMID: 20820218
-
Real-time 4D signal processing and visualization using graphics processing unit on a regular nonlinear-k Fourier-domain OCT system.Opt Express. 2010 May 24;18(11):11772-84. doi: 10.1364/OE.18.011772. Opt Express. 2010. PMID: 20589038 Free PMC article.
-
GPU-accelerated non-uniform fast Fourier transform-based compressive sensing spectral domain optical coherence tomography.Opt Express. 2014 Jun 16;22(12):14871-84. doi: 10.1364/OE.22.014871. Opt Express. 2014. PMID: 24977582 Free PMC article.
-
Fourier phase based depth-resolved nanoscale nuclear architecture mapping for cancer detection.Methods. 2018 Mar 1;136:134-151. doi: 10.1016/j.ymeth.2017.10.011. Epub 2017 Nov 7. Methods. 2018. PMID: 29127043 Free PMC article. Review.
Cited by
-
High-speed OCT light sources and systems [Invited].Biomed Opt Express. 2017 Jan 13;8(2):828-859. doi: 10.1364/BOE.8.000828. eCollection 2017 Feb 1. Biomed Opt Express. 2017. PMID: 28270988 Free PMC article. Review.
-
GPU accelerated real-time multi-functional spectral-domain optical coherence tomography system at 1300 nm.Opt Express. 2012 Jul 2;20(14):14797-813. doi: 10.1364/OE.20.014797. Opt Express. 2012. PMID: 22772175 Free PMC article.
-
GPU-accelerated framework for intracoronary optical coherence tomography imaging at the push of a button.PLoS One. 2015 Apr 16;10(4):e0124192. doi: 10.1371/journal.pone.0124192. eCollection 2015. PLoS One. 2015. PMID: 25880375 Free PMC article.
-
Real-time GPU-accelerated processing and volumetric display for wide-field laser-scanning optical-resolution photoacoustic microscopy.Biomed Opt Express. 2015 Nov 2;6(12):4650-60. doi: 10.1364/BOE.6.004650. eCollection 2015 Dec 1. Biomed Opt Express. 2015. PMID: 26713184 Free PMC article.
-
Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second.Biomed Opt Express. 2012 Dec 1;3(12):3067-86. doi: 10.1364/BOE.3.003067. Epub 2012 Nov 1. Biomed Opt Express. 2012. PMID: 23243560 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous