Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy
- PMID: 20059272
- DOI: 10.1117/1.3275469
Multidistance probe arrangement to eliminate artifacts in functional near-infrared spectroscopy
Abstract
Functional near-infrared spectroscopy has the potential to easily detect cerebral functional hemodynamics. However, in practical fNIRS measurements, a subject's physical or systemic physiological activities often cause undesirable artifacts. Such activities can be evoked even by task execution. In this case, observed artifacts may correlate strongly with the task sequence, and it is difficult to eliminate them by conventional signal filtering techniques. We present a theoretical analysis and Monte Carlo simulations of layered media in which both scattering and absorption changes occur, and show that a multidistance probe arrangement is effective in removing artifacts and extracting functional hemodynamics. The probe arrangement is determined based on simulation results. Artifacts induced by nonfunctional tasks (body tilting, head nodding, and breath holding) are clearly observed when a conventional method is used; such artifacts are appreciably reduced by the proposed method. Signals evoked by single-sided finger movements are observed at both hemispheres when we use a conventional method. On the other hand, localized signals at the primary motor area are observed by the proposed method. A statistically significant increase in oxygenated hemoglobin and decrease in deoxygenated hemoglobin are simultaneously observed at the contralateral primary motor area.
Similar articles
-
RLS adaptive filtering for physiological interference reduction in NIRS brain activity measurement: a Monte Carlo study.Physiol Meas. 2012 Jun;33(6):925-42. doi: 10.1088/0967-3334/33/6/925. Epub 2012 May 3. Physiol Meas. 2012. PMID: 22551687
-
Reduction of global interference of scalp-hemodynamics in functional near-infrared spectroscopy using short distance probes.Neuroimage. 2016 Nov 1;141:120-132. doi: 10.1016/j.neuroimage.2016.06.054. Epub 2016 Jun 30. Neuroimage. 2016. PMID: 27374729
-
Impact of communicative head movements on the quality of functional near-infrared spectroscopy signals: negligible effects for affirmative and negative gestures and consistent artifacts related to raising eyebrows.J Biomed Opt. 2017 Apr 1;22(4):46010. doi: 10.1117/1.JBO.22.4.046010. J Biomed Opt. 2017. PMID: 28451693
-
Monte Carlo study of global interference cancellation by multidistance measurement of near-infrared spectroscopy.J Biomed Opt. 2009 Nov-Dec;14(6):064025. doi: 10.1117/1.3275466. J Biomed Opt. 2009. PMID: 20059263
-
Evoked Hemodynamic Response Estimation to Auditory Stimulus Using Recursive Least Squares Adaptive Filtering with Multidistance Measurement of Near-Infrared Spectroscopy.J Healthc Eng. 2018 Mar 29;2018:7609713. doi: 10.1155/2018/7609713. eCollection 2018. J Healthc Eng. 2018. PMID: 29796235 Free PMC article.
Cited by
-
Removal of motion artifacts originating from optode fluctuations during functional near-infrared spectroscopy measurements.Biomed Opt Express. 2015 Nov 2;6(12):4632-49. doi: 10.1364/BOE.6.004632. eCollection 2015 Dec 1. Biomed Opt Express. 2015. PMID: 26713183 Free PMC article.
-
Further improvement in reducing superficial contamination in NIRS using double short separation measurements.Neuroimage. 2014 Jan 15;85 Pt 1(0 1):127-35. doi: 10.1016/j.neuroimage.2013.01.073. Epub 2013 Feb 9. Neuroimage. 2014. PMID: 23403181 Free PMC article.
-
Analgesic Effects of Compression at Trigger Points Are Associated With Reduction of Frontal Polar Cortical Activity as Well as Functional Connectivity Between the Frontal Polar Area and Insula in Patients With Chronic Low Back Pain: A Randomized Trial.Front Syst Neurosci. 2019 Nov 13;13:68. doi: 10.3389/fnsys.2019.00068. eCollection 2019. Front Syst Neurosci. 2019. PMID: 31798422 Free PMC article.
-
Multiregional functional near-infrared spectroscopy reveals globally symmetrical and frequency-specific patterns of superficial interference.Biomed Opt Express. 2015 Jul 8;6(8):2786-802. doi: 10.1364/BOE.6.002786. eCollection 2015 Aug 1. Biomed Opt Express. 2015. PMID: 26309744 Free PMC article.
-
A validation method for near-infrared spectroscopy based tissue oximeters for cerebral and somatic tissue oxygen saturation measurements.J Clin Monit Comput. 2018 Apr;32(2):269-284. doi: 10.1007/s10877-017-0015-1. Epub 2017 Apr 3. J Clin Monit Comput. 2018. PMID: 28374103 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources