Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006
- PMID: 20059714
- DOI: 10.1111/j.1540-8159.2009.02670.x
Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993-2006
Abstract
Background: Prior studies of cardiac rhythm management devices (pacemakers [PM] and implantable cardioverter defibrillators [ICD]) utilization in the United States have been limited to the Medicare population. We evaluated the national trends for the implantation of PMs and ICDs including the burden of device replacement.
Methods: The Nationwide Inpatient Sample was queried to identify PM and ICD patients between 1993 and 2006 using ICD-9-CM codes, including demographics, health profile, and economic data. The Charlson Comorbidity Index (CCI) and replacement burden were calculated, and changes over time studied.
Results: From 1993 to 2006, 2.4 million patients received a primary PM and 0.8 million received an ICD, while there were 369,000 PM replacements and 74,000 ICD replacements. Women comprised 49% of PM and 24% of ICD patients. The mean ICD replacement burden was 8.4% (range 5-22%) and decreased significantly over time (P < 0.0001) while the replacement burden for PMs was constant (mean = 13.4%, range 11-16%). ICD patients had more comorbidities than PM patients (CCI: 0.8 vs 1.1, P < 0.0001).
Conclusions: The replacement burden for PMs has remained constant, while the replacement burden for ICDs has decreased. This is likely due to the stability of the patient population receiving PMs and technology maturity. Alternatively, the indications for ICD implantation have broadened, resulting in an increased number of primary ICD implantations. The age and comorbidities are increasing in those patients receiving ICDs while the PM population is stable. These data suggest that monitoring of replacement burden is warranted, given the changing populations, their disparate clinical outcomes, and economic implications to the health care system.
Similar articles
-
16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008.J Am Coll Cardiol. 2011 Aug 30;58(10):1001-6. doi: 10.1016/j.jacc.2011.04.033. J Am Coll Cardiol. 2011. PMID: 21867833
-
Cost advantage of dual-chamber versus single-chamber cardioverter-defibrillator implantation.J Am Coll Cardiol. 2005 Sep 6;46(5):850-7. doi: 10.1016/j.jacc.2005.05.061. J Am Coll Cardiol. 2005. PMID: 16139136
-
[The pacemaker and implantable cardioverter-defibrillator registry of the Italian Association of Arrhythmology and Cardiac Pacing - Annual Report 2012].G Ital Cardiol (Rome). 2013 Nov;14(11):784-96. doi: 10.1714/1360.15091. G Ital Cardiol (Rome). 2013. PMID: 24326641 Italian.
-
Costs and quality-of-life effects of implantable cardioverter-defibrillators.Am J Cardiol. 2006 Nov 15;98(10):1409-15. doi: 10.1016/j.amjcard.2006.06.041. Epub 2006 Oct 4. Am J Cardiol. 2006. PMID: 17134641 Review.
-
Clinical applications of magnets on cardiac rhythm management devices.Europace. 2011 Sep;13(9):1222-30. doi: 10.1093/europace/eur137. Epub 2011 May 26. Europace. 2011. PMID: 21616944 Review.
Cited by
-
Interference between surgical magnetic drapes and pacemakers: an observational study comparing commercially available devices and a new magnetically isolated drape.Biomed Eng Online. 2016 Jul 19;15(1):83. doi: 10.1186/s12938-016-0205-y. Biomed Eng Online. 2016. PMID: 27430339 Free PMC article.
-
Safety and efficacy of transvenous lead extraction of very old leads.Interact Cardiovasc Thorac Surg. 2021 Apr 8;32(3):402-407. doi: 10.1093/icvts/ivaa278. Interact Cardiovasc Thorac Surg. 2021. PMID: 33257960 Free PMC article.
-
The pathway to physician reimbursement for cardiac implantable electronic devices (CIEDs): a history and brief synopsis.J Interv Card Electrophysiol. 2013 Mar;36(2):137-44. doi: 10.1007/s10840-012-9747-5. Epub 2012 Dec 15. J Interv Card Electrophysiol. 2013. PMID: 23242735 Review.
-
Incidence of cardiac implantable electronic device infections and migrations in Japan: Results from a 129 institute survey.J Arrhythm. 2016 Aug;32(4):303-7. doi: 10.1016/j.joa.2015.09.006. Epub 2015 Nov 4. J Arrhythm. 2016. PMID: 27588154 Free PMC article.
-
Cardiac implantable electronic device implantation and device-related infection.Europace. 2023 Aug 2;25(9):euad208. doi: 10.1093/europace/euad208. Europace. 2023. PMID: 37572046 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical