Left ventricular ejection fraction and absence of ACE inhibitor/angiotensin II receptor blocker predicts appropriate defibrillator therapy in the primary prevention population
- PMID: 20059719
- DOI: 10.1111/j.1540-8159.2009.02669.x
Left ventricular ejection fraction and absence of ACE inhibitor/angiotensin II receptor blocker predicts appropriate defibrillator therapy in the primary prevention population
Abstract
Introduction: Implantable cardioverter defibrillators (ICD) significantly reduce mortality in patients with left ventricular (LV) dysfunction. However, little is known of the predictors of appropriate device activation in the primary prevention population. The aim of the present study was to determine predictors of appropriate device therapy in patients receiving ICDs for primary prevention.
Methods & results: One hundred twenty-six patients with a left ventricular ejection fraction (LVEF) of < 35% and no prior documented ventricular arrhythmias underwent ICD implantation. The ICD implanted was single chamber in 60 (48%), dual chamber in 10 (8%), and biventricular in 56 (44%) patients and programmed with a single ventricular fibrillation (VF) zone at >180 beats per minute. Mean age was 58 +/- 13 years and mean LVEF was 23 +/- 7%. Fifty-two percent had ischemic cardiomyopathy and 66% were New York Heart Association heart failure class II/III. During a mean follow-up period of 589 +/- 353 days, 17 (13%) patients received appropriate device therapy and three (4%) received inappropriate shocks. Appropriate ICD therapy was associated with reduced LVEF (mean 19.9% vs 23.7%, P = 0.02) and the patients were less likely to have received angiotensin-converting enzyme inhibitor (ACEI) or angiotensin II receptor blockers (AIIRB) (65% vs 90%, P = 0.04). Multivariate analysis revealed lack of ACEI/AIIRB (odds ratio [OR]= 0.06, 95% confidence interval [CI]= 0.01-0.37, P = <0.01) and lower LVEF (OR = 0.88, 95% CI 0.79-0.98, P = 0.02) predicted appropriate device activation. There was no difference in transplant-free survival between the appropriate therapy and no/inappropriate therapy groups, LVEF <20% and LVEF >20% group, and lack of ACEI/AIIRB and ACEI/AIIRB group.
Conclusion: Appropriate device activation occurred in 13% of patients in a primary prevention population. LVEF and absence of ACEI/AIIRB predicted appropriate ICD therapy.
Similar articles
-
Factors predisposing to ventricular tachyarrhythmia leading to appropriate ICD intervention in patients with coronary artery disease or non-ischaemic dilated cardiomyopathy.Kardiol Pol. 2012;70(12):1264-75. Kardiol Pol. 2012. PMID: 23264245
-
Predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in primary prevention patients with ischemic and nonischemic cardiomyopathy.Pacing Clin Electrophysiol. 2010 Mar;33(3):320-9. doi: 10.1111/j.1540-8159.2009.02566.x. Epub 2009 Oct 1. Pacing Clin Electrophysiol. 2010. PMID: 19796352
-
Heart failure and the risk of shocks in patients with implantable cardioverter defibrillators: results from the Triggers Of Ventricular Arrhythmias (TOVA) study.Circulation. 2004 Mar 23;109(11):1386-91. doi: 10.1161/01.CIR.0000120703.99433.1E. Epub 2004 Mar 1. Circulation. 2004. PMID: 14993132
-
Use of implantable cardioverter-defibrillators.Future Cardiol. 2010 Nov;6(6):859-70. doi: 10.2217/fca.10.99. Future Cardiol. 2010. PMID: 21142641 Review.
-
Meta-analysis of Risk of Ventricular Arrhythmias After Improvement in Left Ventricular Ejection Fraction During Follow-Up in Patients With Primary Prevention Implantable Cardioverter Defibrillators.Am J Cardiol. 2017 Jul 15;120(2):279-286. doi: 10.1016/j.amjcard.2017.04.020. Epub 2017 Apr 27. Am J Cardiol. 2017. PMID: 28532779 Review.
Cited by
-
Angiotensin receptor antagonists to prevent sudden death in heart failure: does the dose matter?ISRN Cardiol. 2014 Feb 6;2014:652421. doi: 10.1155/2014/652421. eCollection 2014. ISRN Cardiol. 2014. PMID: 24653841 Free PMC article. Review.
-
Increased Platelet-to-Lymphocyte Ratios and Low Relative Lymphocyte Counts Predict Appropriate Shocks in Heart Failure Patients with ICDs.Acta Cardiol Sin. 2016 Sep;32(5):542-549. doi: 10.6515/acs20151012b. Acta Cardiol Sin. 2016. PMID: 27713602 Free PMC article.
-
Follow-up of implantable cardioverter-defibrillator therapy: comparison of coronary artery disease and dilated cardiomyopathy.Neth Heart J. 2014 Oct;22(10):431-7. doi: 10.1007/s12471-014-0595-z. Neth Heart J. 2014. PMID: 25169578 Free PMC article.
-
Effect of angiotensin-converting enzyme inhibitors and receptor blockers on appropriate implantable cardiac defibrillator shock in patients with severe systolic heart failure (from the GRADE Multicenter Study).Am J Cardiol. 2015 Apr 1;115(7):924-31. doi: 10.1016/j.amjcard.2015.01.020. Epub 2015 Jan 15. Am J Cardiol. 2015. PMID: 25682436 Free PMC article. Clinical Trial.
-
Heart failure treatment in patients with cardiac implantable electronic devices: Opportunity for improvement.Heart Rhythm O2. 2021 Dec 17;2(6Part B):698-709. doi: 10.1016/j.hroo.2021.09.010. eCollection 2021 Dec. Heart Rhythm O2. 2021. PMID: 34988519 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous