The significance of repeat testing in Turkish blood donors screened with HBV, HCV and HIV immunoassays and the importance of S/CO ratios in the interpretation of HCV/HIV screening test results and as a determinant for further confirmatory testing
- PMID: 20059750
- DOI: 10.1111/j.1365-3148.2009.00987.x
The significance of repeat testing in Turkish blood donors screened with HBV, HCV and HIV immunoassays and the importance of S/CO ratios in the interpretation of HCV/HIV screening test results and as a determinant for further confirmatory testing
Abstract
The purpose of this study was to investigate the intra-assay correlations amongst initial reactive and repeat screening results used in enzyme immunoassays (EIAs) for hepatitis B virus (HBV), hepatitis C virus (HCV) and HIV in blood donors. This study evaluated the value of using the power of the signal to cut-off (S/CO) ratio index for confirming anti-HCV/HIV reactive screening results, thereby touching upon the utility of S/CO indices in determining whether further confirmatory testing was necessary. Screening test results of the 72,695 blood donors were evaluated over a 1-year period. Correlation analysis among each initial test and retests was done by Pearson r test. Appropriate S/CO values to determine the need of the confirmation testing was investigated by ROC analyses. EIA intra-assay correlations were of statistical significance and were determined as follows: 0.948 for anti-HCV, 0.827 for anti-HIV and 0.948 for HBsAg. The threshold S/CO ratio values which predicted more than 95% of the confirmation test result were 3.8 for HCV and 5.6 for HIV. We were able to demonstrate a strong level of intra-assay correlation amongst EIAs, thereby eliminating the need for repetition of the screening test. Hence, we suggest that repeat screening should only be limited to HBV and HIV tests with low EIA S/CO ratios. Thus, using the power of the S/CO ratio in determining the need for HCV confirmation testing can be a cost-effective measure, especially if the S/CO value is >or=3.8.
Similar articles
-
Significance of the signal-to-cutoff ratios of anti-hepatitis C virus enzyme immunoassays in screening of Chinese blood donors.Transfusion. 2005 Nov;45(11):1816-22. doi: 10.1111/j.1537-2995.2005.00611.x. Transfusion. 2005. PMID: 16271110
-
[Short communication: comparison of two different assays for the investigation of HBsAG, anti-HCV and anti-HIV in blood donors].Mikrobiyol Bul. 2006 Oct;40(4):363-7. Mikrobiyol Bul. 2006. PMID: 17205694 Turkish.
-
[Seroprevalence of hepatitis B and C virus, human immunodeficiency virus and syphilis in the blood donors].Mikrobiyol Bul. 2004 Oct;38(4):445-8. Mikrobiyol Bul. 2004. PMID: 15700672 Turkish.
-
Should HBV DNA NAT replace HBsAg and/or anti-HBc screening of blood donors?Transfus Clin Biol. 2004 Feb;11(1):26-32. doi: 10.1016/j.tracli.2003.12.003. Transfus Clin Biol. 2004. PMID: 14980546 Review.
-
[Human immunodeficiency virus (HIV) and Hepatitis C virus (HCV) testing among injecting drug users].Orv Hetil. 2011 Jan 23;152(4):124-30. doi: 10.1556/OH.2011.29019. Orv Hetil. 2011. PMID: 21224188 Review. Hungarian.
Cited by
-
CDC Laboratory Recommendations for Syphilis Testing, United States, 2024.MMWR Recomm Rep. 2024 Feb 8;73(1):1-32. doi: 10.15585/mmwr.rr7301a1. MMWR Recomm Rep. 2024. PMID: 38319847 Free PMC article.
-
HIV serology signal-to-cutoff ratio as a rapid method to predict confirmation of HIV infection.Eur J Clin Microbiol Infect Dis. 2018 Aug;37(8):1589-1593. doi: 10.1007/s10096-018-3290-y. Epub 2018 Jun 3. Eur J Clin Microbiol Infect Dis. 2018. PMID: 29862422
-
Analytical performance of three diagnostic reagents for HBsAg on an automatic ELISA analyzer.J Clin Lab Anal. 2018 Jan;32(1):e22159. doi: 10.1002/jcla.22159. Epub 2017 Feb 10. J Clin Lab Anal. 2018. PMID: 28187244 Free PMC article.
-
An Analysis of Predictive Sample-to-Cutoff Index for HIV Infection Confirmation Using Elecsys® HIV Combi PT Assay.Int J Clin Pract. 2022 Aug 10;2022:5097189. doi: 10.1155/2022/5097189. eCollection 2022. Int J Clin Pract. 2022. PMID: 36016828 Free PMC article.
-
A signal-to-cutoff ratio in the Abbott architect HIV Ag/Ab Combo assay that predicts subsequent confirmation of HIV-1 infection in a low-prevalence setting.J Clin Microbiol. 2015 May;53(5):1709-11. doi: 10.1128/JCM.03583-14. Epub 2015 Feb 11. J Clin Microbiol. 2015. PMID: 25673794 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical