Pervaporation in chemical analysis
- PMID: 20060529
- DOI: 10.1016/j.chroma.2009.12.043
Pervaporation in chemical analysis
Abstract
Unlike thermal processes such as distillation, pervaporation relies on the relative rates of solute permeation through a membrane and is a combination of evaporation and gas diffusion. The analytical pervaporation systems consist of a membrane module suitable for liquid sample introduction and a vacuum (or a sweeping gas) on the permeate side. It has been used in a wide range of applications including the analysis of various organic and inorganic compounds, and sample concentration. It has been directly interfaced with gas chromatography, spectrophotometry, capillary electrophoresis, electrochemical detectors, liquid chromatography, and mass spectrometry. A wide range of liquids, slurries, and solids samples has been analyzed using these techniques. This review highlights the basic principles of the pervaporation and the state of its current development as applied to analytical chemistry.
Copyright 2009 Elsevier B.V. All rights reserved.
Similar articles
-
Liquid-liquid extraction in flow analysis: A critical review.Anal Chim Acta. 2009 Oct 12;652(1-2):54-65. doi: 10.1016/j.aca.2009.05.042. Epub 2009 Jun 7. Anal Chim Acta. 2009. PMID: 19786170 Review.
-
Development of a membraneless extraction module for the extraction of volatile compounds: application in the chromatographic analysis of vicinal diketones in beer.Talanta. 2010 Apr 15;81(1-2):372-6. doi: 10.1016/j.talanta.2009.12.011. Epub 2009 Dec 16. Talanta. 2010. PMID: 20188933
-
Extraction of organic compounds with room temperature ionic liquids.J Chromatogr A. 2010 Apr 16;1217(16):2268-86. doi: 10.1016/j.chroma.2009.09.011. Epub 2009 Sep 10. J Chromatogr A. 2010. PMID: 19766228 Review.
-
Automated, on-line membrane extraction.J Chromatogr A. 2007 Jun 8;1152(1-2):199-214. doi: 10.1016/j.chroma.2006.12.047. Epub 2006 Dec 20. J Chromatogr A. 2007. PMID: 17275830 Review.
-
A micro circulating PCR chip using a suction-type membrane for fluidic transport.Biomed Microdevices. 2009 Apr;11(2):359-67. doi: 10.1007/s10544-008-9242-z. Biomed Microdevices. 2009. PMID: 18975094
Cited by
-
Novel Approach to Sample Preconcentration by Solvent Evaporation in Flow Analysis.Molecules. 2020 Apr 18;25(8):1886. doi: 10.3390/molecules25081886. Molecules. 2020. PMID: 32325764 Free PMC article.
-
Home-Made Membraneless Vaporization Gas-Liquid Separator for Colorimetric Determination of Ethanol in Alcoholic Beverages.J Anal Methods Chem. 2022 Mar 31;2022:7346253. doi: 10.1155/2022/7346253. eCollection 2022. J Anal Methods Chem. 2022. PMID: 35402059 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources