The role of the cemented all-polyethylene tibial component in total knee replacement: a 30-year patient follow-up and review of the literature
- PMID: 20060725
- DOI: 10.1016/j.knee.2009.11.008
The role of the cemented all-polyethylene tibial component in total knee replacement: a 30-year patient follow-up and review of the literature
Abstract
Use of an all-polyethylene tibial component in primary total knee arthroplasty remains an attractive option considering the reported durability of the construct, the lowered cost compared to modular metal-backed tibia, and the elimination of backside wear. The two major intra-operative disadvantages include the inability to alter the tibial component thickness after permanent implant placement and the inability to use varus-valgus constrained designs. The long-term disadvantage is the inability to perform a modular insert exchange should this be required. We report the 30-year outcome of a single patient using the duopatellar total knee replacement system. Based on a critical review of the literature we would recommend use in patients 80 years of age or older, consideration in patients 75 to 79 years, and possibly in younger yet less active patients. These three groups would be the least likely to require a modular tibial liner exchange in their lifetime.
Copyright © 2009 Elsevier B.V. All rights reserved.
Similar articles
-
Should we reconsider all-polyethylene tibial implants in total knee replacement?J Bone Joint Surg Br. 2006 Dec;88(12):1596-602. doi: 10.1302/0301-620X.88B12.17695. J Bone Joint Surg Br. 2006. PMID: 17159170 Clinical Trial.
-
A randomized controlled trial comparing "high-flex" vs "standard" posterior cruciate substituting polyethylene tibial inserts in total knee arthroplasty.J Arthroplasty. 2009 Sep;24(6 Suppl):33-8. doi: 10.1016/j.arth.2009.03.013. Epub 2009 May 15. J Arthroplasty. 2009. PMID: 19447001 Clinical Trial.
-
Survivorship of cemented total knee arthroplasty.Clin Orthop Relat Res. 1997 Dec;(345):79-86. Clin Orthop Relat Res. 1997. PMID: 9418624
-
The all-polyethylene tibial component in primary total knee arthroplasty.J Bone Joint Surg Am. 2010 Feb;92(2):478-87. doi: 10.2106/JBJS.I.00842. J Bone Joint Surg Am. 2010. PMID: 20124081 Review.
-
Cementless Porous Tantalum Monoblock Tibia vs Cemented Modular Tibia in Primary Total Knee Arthroplasty: A Meta-Analysis.J Arthroplasty. 2017 Feb;32(2):666-674. doi: 10.1016/j.arth.2016.09.011. Epub 2016 Sep 28. J Arthroplasty. 2017. PMID: 27776898 Review.
Cited by
-
Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.Acta Orthop. 2011 Oct;82(5):589-95. doi: 10.3109/17453674.2011.618913. Epub 2011 Sep 6. Acta Orthop. 2011. PMID: 21895503 Free PMC article. Clinical Trial.
-
Modular versus nonmodular tibial inserts in total knee arthroplasty: what are the differences?Ann Transl Med. 2017 May;5(10):225. doi: 10.21037/atm.2017.02.25. Ann Transl Med. 2017. PMID: 28603740 Free PMC article. No abstract available.
-
Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?Knee Surg Sports Traumatol Arthrosc. 2012 Aug;20(8):1438-49. doi: 10.1007/s00167-011-1682-y. Epub 2011 Oct 5. Knee Surg Sports Traumatol Arthrosc. 2012. PMID: 21971938
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical