Optical design of a variable view imaging system with the combination of a telecentric scanner and double wedge prisms
- PMID: 20062511
- DOI: 10.1364/AO.49.000239
Optical design of a variable view imaging system with the combination of a telecentric scanner and double wedge prisms
Abstract
Recent developments in micro-electro-mechanical systems and biotechnology have presented an emerging need for observation of dynamic targets in three-dimensional space. Unfortunately, conventional microscopes with fixed optical parameters have difficulty supplying sufficient vision information because of occlusion, small field of view, and low depth resolution. This paper introduces the design of a variable view imaging system that can supply a flexible view with a relatively large zenith angle and simple kinematics. Because of several performance factors, a multiobjective optimization process is applied to achieve an appropriate design. A prototype system is developed and used to verify the proposed design.
Similar articles
-
A hyperspectral fluorescence system for 3D in vivo optical imaging.Phys Med Biol. 2006 Apr 21;51(8):2029-43. doi: 10.1088/0031-9155/51/8/005. Epub 2006 Apr 3. Phys Med Biol. 2006. PMID: 16585843
-
A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus.IEEE Trans Med Imaging. 2005 Nov;24(11):1492-9. doi: 10.1109/TMI.2005.856746. IEEE Trans Med Imaging. 2005. PMID: 16279085
-
Automatic image performance balancing in lens optimization.Opt Express. 2010 May 24;18(11):11574-88. doi: 10.1364/OE.18.011574. Opt Express. 2010. PMID: 20589018
-
Role of optics in the accuracy of depth-from-defocus systems.J Opt Soc Am A Opt Image Sci Vis. 2007 Apr;24(4):967-72. doi: 10.1364/josaa.24.000967. J Opt Soc Am A Opt Image Sci Vis. 2007. PMID: 17361282 Review.
-
Physics and engineering aspects of cell and tissue imaging systems: microscopic devices and computer assisted diagnosis.Stud Health Technol Inform. 2013;185:1-22. Stud Health Technol Inform. 2013. PMID: 23542929 Review.
Cited by
-
An Automatic Calibration Method for the Field of View Aberration in a Risley-Prism-Based Image Sensor.Sensors (Basel). 2023 Sep 9;23(18):7777. doi: 10.3390/s23187777. Sensors (Basel). 2023. PMID: 37765834 Free PMC article.
-
Visual perception of wind hazards using cycloidal scanning LiDAR system.Sci Rep. 2025 Feb 11;15(1):5067. doi: 10.1038/s41598-025-89112-y. Sci Rep. 2025. PMID: 39934349 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources