Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Apr;35(4):434-41.
doi: 10.1002/uog.7506.

Influence of ultrasound-to-delivery interval and maternal-fetal characteristics on validity of estimated fetal weight

Affiliations
Free article

Influence of ultrasound-to-delivery interval and maternal-fetal characteristics on validity of estimated fetal weight

J M Cohen et al. Ultrasound Obstet Gynecol. 2010 Apr.
Free article

Abstract

Objectives: To explore the effects of ultrasound-to-delivery interval and maternal-fetal characteristics on the distribution of measurement error in estimated fetal weights (EFWs), and to determine the predictive ability of EFW for diagnosis of small-for-gestational age (SGA) and large-for-gestational age (LGA) among infants delivered within 1 day of an ultrasound examination.

Methods: Percentage differences between EFW and birth weights were calculated in 3697 pregnancies. Linear regression was used to compare the accuracy of EFW for births on each of the 6 days after an ultrasound scan with the accuracy observed among births on the same day. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value for diagnosis of SGA and LGA according to EFW was assessed.

Results: The mean +/- SD percentage difference among deliveries within 1 day of the last ultrasound scan was 0.2 +/- 9.0%. Mean percentage differences were not significantly different from day 0 on days 1, 2 and 3; however, combining the data from these 4 days obscured a slight bias towards an overestimation of weight evident on day 0 and day 1. Among deliveries within 1 day of an ultrasound scan, the PPV was 61% for SGA diagnosis and 54% for LGA diagnosis.

Conclusion: Combining data from births > 1 day after the last ultrasound examination may lead to a false conclusion that there is systematic underestimation of weight. EFW tended to underestimate the weight of macrosomic fetuses and overestimate that of small fetuses which limited sensitivity and PPV. Maternal-fetal characteristics are weak predictors of individual errors in EFW.

PubMed Disclaimer

Similar articles

Cited by

Publication types

LinkOut - more resources