Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting
- PMID: 20072804
- DOI: 10.1007/s10840-009-9460-1
Use of a novel needle wire in patients undergoing transseptal puncture associated with severe septal tenting
Abstract
Introduction: An increasing number of patients undergo left atrial ablation procedures, since several approaches have proven efficacy in the treatment of atrial fibrillation. Although transseptal catheterization was generally shown be a safe technique, it harbors the principal risk of cardiac injury. Therefore, there is a need for a safe and effective tool to enable transseptal puncture in difficult cases as well.
Methods and results: In 158 consecutive patients, a transseptal puncture was intended for mapping and ablation of left atrial tachycardias. In seven patients of this series transseptal puncture using different sheaths and needle designs, the operators failed to cross the interatrial septum as a result of severe tenting. Three patients were known to have a septal aneurysm; a redo procedure was performed in two patients. In the remaining patients, there was no obvious explanation for the difficulty in crossing the interatrial septum conventionally. In all seven patients, a 120-cm-long nitinol guidewire ("needle wire") with a 0.014-inch diameter was used to cross the atrial septum with the following idea: after tenting the fossa ovalis with the transseptal dilator and the Brockenbrough needle positioned just inside the tip, effortless advancement of the needle wire perforates the membranous fossa. Unsupported by the needle and dilator, the tip of the wire immediately assumes a "J" shape, rendering it incapable of further tissue penetration after its entry into the left atrium. In all seven patients, the needle wire could be placed into a left pulmonary vein. In five patients, a single attempt was sufficient to reach the left atrium with the wire, two patients needed two and three attempts, respectively. No complications occurred.
Conclusions: Additional use of a needle wire to perform transseptal puncture in a subset of patients at higher risk for complications appears safe and effective.
Similar articles
-
Initial experience using a radiofrequency powered transseptal needle.J Cardiovasc Electrophysiol. 2010 Apr;21(4):423-7. doi: 10.1111/j.1540-8167.2009.01656.x. Epub 2009 Nov 17. J Cardiovasc Electrophysiol. 2010. PMID: 19925604 Clinical Trial.
-
Transseptal catheterization using a powered radiofrequency transseptal needle.J Interv Card Electrophysiol. 2010 Jan;27(1):15-6. doi: 10.1007/s10840-009-9414-7. Epub 2009 Jun 16. J Interv Card Electrophysiol. 2010. PMID: 19529885
-
Wire- and needle potentials facilitating transseptal puncture.J Electrocardiol. 2017 May-Jun;50(3):358-367. doi: 10.1016/j.jelectrocard.2017.01.004. Epub 2017 Jan 15. J Electrocardiol. 2017. PMID: 28109525 Clinical Trial.
-
Transseptal Puncture: Devices, Techniques, and Considerations for Specific Interventions.Curr Cardiol Rep. 2019 May 7;21(6):52. doi: 10.1007/s11886-019-1136-6. Curr Cardiol Rep. 2019. PMID: 31065869 Review.
-
Transseptal Access to the Left Atrium: Tips and Tricks to Keep it Safe Derived from Single Operator Experience and Review of the Literature.Curr Cardiol Rev. 2017;13(4):305-318. doi: 10.2174/1573403X13666170927122036. Curr Cardiol Rev. 2017. PMID: 28969539 Free PMC article. Review.
Cited by
-
Complication prevention in ablation procedures: How to perform transseptal puncture safely in case of atrial septum aneurysm.HeartRhythm Case Rep. 2019 Nov 15;5(11):529-533. doi: 10.1016/j.hrcr.2019.06.004. eCollection 2019 Nov. HeartRhythm Case Rep. 2019. PMID: 31890566 Free PMC article. No abstract available.
-
Utility and safety of the SafeSept™ transseptal guidewire for electrophysiology studies with catheter ablation in pediatric and congenital heart disease.J Interv Card Electrophysiol. 2017 Apr;48(3):369-374. doi: 10.1007/s10840-017-0224-z. Epub 2017 Jan 14. J Interv Card Electrophysiol. 2017. PMID: 28091832
-
Modified Transseptal Puncture Technique in Challenging Septa: A Randomized Comparison to Conventional Technique.Biomed Res Int. 2017;2017:2351925. doi: 10.1155/2017/2351925. Epub 2017 Jan 30. Biomed Res Int. 2017. PMID: 28251152 Free PMC article. Clinical Trial.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical