Functional comparison of hemoglobin purified by different methods and their biophysical implications
- PMID: 20073089
- DOI: 10.1002/bit.22659
Functional comparison of hemoglobin purified by different methods and their biophysical implications
Abstract
Hemoglobin (Hb) that is purified from red blood cells (RBCs) is commonly subjected to harsh processing conditions, such as high temperatures and extensive column separation, which may damage the Hb by altering the heme prosthetic group and/or the Hb protein structure. In this study, bovine and human Hb purified by tangential flow filtration (TFF) was compared to commercial preparations of human Hb (Hemosol, Inc., Toronto, Canada) and bovine Hb (Biopure, Inc., Cambridge, MA). Purified Hbs were characterized by measuring their overall purity (SDS-PAGE, SEC, and ESI-MS), susceptibility to oxidation (k(ox)), responses to physiological conditions (pH, [Cl(-)], [IHP], and T), and ligand binding kinetics (O(2), NO, and CO). All Hbs evaluated possessed comparable biophysical properties, however, a small amount of catalase was detected in the TFF-purified Hbs that reduced the rate of autoxidation. Mass changes observed by mass spectrometry suggest that structural alterations may be introduced into Hbs that are purified by extensive chromatographic separations. These results demonstrate that TFF is a suitable process for the purification of Hb from RBCs with a quality equivalent to that of commercial Hb preparations that employ more extensive purification strategies. This work also shows that TFF can yield highly pure Hb which can be used for Hb-based O(2) carrier synthesis.
Similar articles
-
Exposure of hydrophobic moieties promotes the selective degradation of hydrogen peroxide-modified hemoglobin by the multicatalytic proteinase complex, proteasome.Arch Biochem Biophys. 1994 Jun;311(2):329-41. doi: 10.1006/abbi.1994.1245. Arch Biochem Biophys. 1994. PMID: 8203895
-
Tangential flow filtration of hemoglobin.Biotechnol Prog. 2009 Jan-Feb;25(1):189-99. doi: 10.1002/btpr.119. Biotechnol Prog. 2009. PMID: 19224583 Free PMC article.
-
Purification of hemoglobin by tangential flow filtration with diafiltration.Biotechnol Prog. 2009 Sep-Oct;25(5):1402-10. doi: 10.1002/btpr.217. Biotechnol Prog. 2009. PMID: 19621471 Free PMC article.
-
Analysis of major protein-protein and protein-metal complexes of erythrocytes directly from cell lysate utilizing capillary electrophoresis mass spectrometry.Anal Chem. 2008 Sep 15;80(18):7169-73. doi: 10.1021/ac801158q. Epub 2008 Aug 19. Anal Chem. 2008. PMID: 18710259
-
Nonvertebrate hemoglobins: functions and molecular adaptations.Physiol Rev. 2001 Apr;81(2):569-628. doi: 10.1152/physrev.2001.81.2.569. Physiol Rev. 2001. PMID: 11274340 Review.
Cited by
-
Oxygen delivery during extreme anemia with ultra-pure earthworm hemoglobin.Life Sci. 2012 Oct 29;91(17-18):852-9. doi: 10.1016/j.lfs.2012.08.036. Epub 2012 Sep 13. Life Sci. 2012. PMID: 22982347 Free PMC article.
-
Liposomes surface conjugated with human hemoglobin target delivery to macrophages.Biotechnol Bioeng. 2012 Mar;109(3):823-9. doi: 10.1002/bit.24340. Epub 2011 Nov 6. Biotechnol Bioeng. 2012. PMID: 22012493 Free PMC article.
-
Biophysical properties and oxygenation potential of high-molecular-weight glutaraldehyde-polymerized human hemoglobins maintained in the tense and relaxed quaternary states.Tissue Eng Part A. 2011 Apr;17(7-8):927-40. doi: 10.1089/ten.TEA.2010.0353. Epub 2011 Jan 16. Tissue Eng Part A. 2011. PMID: 20979534 Free PMC article.
-
Simple method for preparing poly(ethylene glycol)-surface-conjugated liposome-encapsulated hemoglobins: physicochemical properties, long-term storage stability, and their reactions with O2, CO, and NO.Langmuir. 2011 Jul 19;27(14):8829-40. doi: 10.1021/la201246m. Epub 2011 Jun 16. Langmuir. 2011. PMID: 21678920 Free PMC article.
-
Purification of hemoglobin from red blood cells using tangential flow filtration and immobilized metal ion affinity chromatography.J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Jan 15;879(2):131-8. doi: 10.1016/j.jchromb.2010.11.021. Epub 2010 Dec 17. J Chromatogr B Analyt Technol Biomed Life Sci. 2011. PMID: 21195679 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources