Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomograph
- PMID: 20079538
- DOI: 10.1016/j.ophtha.2009.08.039
Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomograph
Abstract
Purpose: To evaluate the reproducibility of peripapillary retinal nerve fiber layer thickness (RNFLT) and ganglion cell complex (GCC) measurements made with the RTVue-100 Fourier-domain optical coherence tomography (OCT) device (Optovue, Inc., Fremont, CA) and to determine the influence of 4 factors: pupil dilation, subject age, experience in imaging examinations, and glaucoma severity.
Design: Prospective study for evaluation of a diagnostic test.
Participants: Thirty-seven hospital-based participants (14 normal and ocular hypertensive subjects, 11 patients with moderate and 12 with severe glaucoma), all experienced in imaging examinations, and 40 consecutive screening trial participants lacking such experience.
Methods: One eye of all participants was imaged 5 times. For the hospital-based participants, on the same day the measurement series was repeated after pupil dilation. For determination of intersession reproducibility, measurements were performed again 3 months later.
Main outcome measures: Intrasession and intersession coefficient of variation (CV), intraclass correlation coefficient (ICC), intratest variability, and test-retest variability.
Results: For the average and quadrant RNFLT parameters and the GCC parameters, intrasession ICC varied between 93.9% and 99.0%, intrasession CV between 1.95% and 5.69%, and intratest variability varied between 3.11 and 9.13 microm. Most thickness values, all intrasession CV and intratest variability values, and the signal strength index were not changed significantly after pupil dilation. Intrasession CV of the 16 peripapillary RNFLT sectors varied between 4.90% and 11.66%. Most intrasession CV values increased significantly with increased disease severity, but intratest variability for average RNFLT and the quadrant RNFLT parameters, which are used for statistical comparison with the normative database, were unaffected by the severity of glaucoma. Patient age and experience in imaging examinations had no influence on intrasession CV. Intratest variability and intrasession CV represented 79.1% to 98.6% and 77.1% to 95.0% of test-retest variability and intervisit CV, respectively, for the average and quadrant RNFLT and the GCC parameters.
Conclusions: Intrasession and intersession reproducibility of RNFLT and GCC measurements with the RTVue-100 OCT are satisfactory for diagnostic purposes, both in normals and in patients with different glaucoma severity. Pupil dilation, age, and experience in imaging examinations did not influence reproducibility in a clinically significant manner.
Financial disclosure(s): Proprietary or commercial disclosure may be found after the references.
Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Comparison of repeatability of retinal nerve fiber layer thickness measurement made using the RTVue Fourier-domain optical coherence tomograph and the GDx scanning laser polarimeter with variable or enhanced corneal compensation.J Glaucoma. 2010 Aug;19(6):412-7. doi: 10.1097/IJG.0b013e3181bdb549. J Glaucoma. 2010. PMID: 19855292
-
Reproducibility of peripapillary retinal nerve fiber thickness measurements with stratus OCT in glaucomatous eyes.Ophthalmology. 2008 Apr;115(4):661-666.e4. doi: 10.1016/j.ophtha.2007.05.035. Epub 2007 Aug 13. Ophthalmology. 2008. PMID: 17706287
-
Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography: a variability and diagnostic performance study.Ophthalmology. 2009 Jul;116(7):1257-63, 1263.e1-2. doi: 10.1016/j.ophtha.2009.04.013. Epub 2009 May 22. Ophthalmology. 2009. PMID: 19464061
-
[Analysis of macular ganglion cell complex (GCC) with spectral-domain optical coherence tomography (SD-OCT) in glaucoma].J Fr Ophtalmol. 2013 Apr;36(4):299-309. doi: 10.1016/j.jfo.2013.01.005. Epub 2013 Mar 29. J Fr Ophtalmol. 2013. PMID: 23541535 Review. French.
-
Macular imaging with optical coherence tomography in glaucoma.Surv Ophthalmol. 2020 Nov-Dec;65(6):597-638. doi: 10.1016/j.survophthal.2020.03.002. Epub 2020 Mar 19. Surv Ophthalmol. 2020. PMID: 32199939 Free PMC article. Review.
Cited by
-
Diagnostic ability of retinal ganglion cell complex, retinal nerve fiber layer, and optic nerve head measurements by Fourier-domain optical coherence tomography.Graefes Arch Clin Exp Ophthalmol. 2011 Jul;249(7):1039-45. doi: 10.1007/s00417-010-1585-5. Epub 2011 Jan 15. Graefes Arch Clin Exp Ophthalmol. 2011. PMID: 21240522
-
The role of optical coherence tomography angiography in moderate and advanced primary open-angle glaucoma.Int Ophthalmol. 2022 Dec;42(12):3645-3659. doi: 10.1007/s10792-022-02360-z. Epub 2022 May 17. Int Ophthalmol. 2022. PMID: 35579770
-
Comparison of macular ganglion cell complex thickness to total retinal thickness ratio between Hungarian and Japanese eyes.Jpn J Ophthalmol. 2013 Nov;57(6):540-5. doi: 10.1007/s10384-013-0273-5. Epub 2013 Aug 27. Jpn J Ophthalmol. 2013. PMID: 23982214
-
Imaging of the optic nerve and retinal nerve fiber layer: an essential part of glaucoma diagnosis and monitoring.Surv Ophthalmol. 2014 Jul-Aug;59(4):458-67. doi: 10.1016/j.survophthal.2013.04.007. Epub 2013 Oct 16. Surv Ophthalmol. 2014. PMID: 24388709 Free PMC article.
-
Intra- and inter-visit reproducibility of ganglion cell-inner plexiform layer measurements using handheld optical coherence tomography in children with optic pathway gliomas.Am J Ophthalmol. 2014 Nov;158(5):916-23. doi: 10.1016/j.ajo.2014.07.029. Epub 2014 Jul 25. Am J Ophthalmol. 2014. PMID: 25068639 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical