Epidemiology and diagnosis of endograft infection
- PMID: 20081758
Epidemiology and diagnosis of endograft infection
Abstract
Endograft infection is reported to occur in between 0.2 and 0.7 of patients and in general presents either within four months of endograft implantation of after more than 12 months. Review of all cases reported to date reveals three modes of presentation: approximately one third of patients present with evidence of an aorto-enteric fistula (although less than half of these present with gastrointestinal haemorrhage), one third present with non specific signs of low grade sepsis (malaise, weight loss) and the remainder with evidence of severe systemic sepsis. Infection is most commonly attributed to Staphylococcus aureus. Diagnosis relies on a high index of suspicion, imaging of the aorta and periaortic tissues (computed tomography or magnetic resonance imaging) and bacteriological culture. This paper presents a detailed analysis of the features of all cases reported to date and examines the aetiology, pathogenesis and imaging of endograft infection and aorto-enteric fistula.
Similar articles
-
Management of thoracic endograft infection.J Cardiovasc Surg (Torino). 2010 Feb;51(1):15-31. J Cardiovasc Surg (Torino). 2010. PMID: 20081759 Review.
-
The relevance of aortic endograft prosthetic infection.J Vasc Surg. 2011 Aug;54(2):327-33. doi: 10.1016/j.jvs.2010.12.067. Epub 2011 Mar 11. J Vasc Surg. 2011. PMID: 21397443
-
Graft infection after endovascular abdominal aortic aneurysm repair.J Vasc Surg. 2011 Jul;54(1):58-63. doi: 10.1016/j.jvs.2010.11.111. Epub 2011 Feb 2. J Vasc Surg. 2011. PMID: 21292428
-
Management of a thoracic endograft infection through an ascending to descending extra-anatomic aortic bypass and endograft explantation.J Vasc Surg. 2010 Jan;51(1):207-9. doi: 10.1016/j.jvs.2009.07.097. Epub 2009 Sep 26. J Vasc Surg. 2010. PMID: 19782515
-
How to manage infected aortic endografts.J Cardiovasc Surg (Torino). 2013 Oct;54(5):595-604. J Cardiovasc Surg (Torino). 2013. PMID: 24002389 Review.
Cited by
-
Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus.Case Rep Vasc Med. 2016;2016:7597265. doi: 10.1155/2016/7597265. Epub 2016 Jan 24. Case Rep Vasc Med. 2016. PMID: 26904354 Free PMC article.
-
Imaging work-up and endovascular treatment options for aorto-enteric fistula.Cardiovasc Diagn Ther. 2018 Apr;8(Suppl 1):S200-S207. doi: 10.21037/cdt.2017.10.05. Cardiovasc Diagn Ther. 2018. PMID: 29850432 Free PMC article. Review.
-
Stent-Graft Removal and Extra-Anatomical Bypass for the Treatment of Stent-Graft Infection after Endovascular Aneurysm Repair.Ann Vasc Dis. 2022 Mar 25;15(1):72-76. doi: 10.3400/avd.cr.21-00106. Ann Vasc Dis. 2022. PMID: 35432657 Free PMC article.
-
Delayed Infected Viabahn Stent Graft With Abscess Formation in Superficial Femoral Artery.Korean Circ J. 2025 Apr;55(4):359-361. doi: 10.4070/kcj.2024.0388. Korean Circ J. 2025. PMID: 40302507 Free PMC article. No abstract available.
-
A multidisciplinary approach: Case report of an abdominal aortic aneurysm with type IIIA endoleak in the setting of cholangitis.SAGE Open Med Case Rep. 2023 Aug 29;11:2050313X231194143. doi: 10.1177/2050313X231194143. eCollection 2023. SAGE Open Med Case Rep. 2023. PMID: 37654556 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources