Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR)
- PMID: 20081765
Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR)
Abstract
Late rupture incidence following endovascular repair (EVAR) of abdominal aortic aneurysm does not appear to decrease with time, mandating life-long surveillance. Popular regimes based on computed tomography (CT) originated in early registry and randomised trial protocols and are not evidence-based. We evaluated the radiation burden (and implications) associated with "conventional" CT surveillance and explored alternative surveillance paradigms. An EVAR program comprising planning CT, EVAR and surveillance CT at 1, 3, 6 and 12 months and yearly thereafter, equates to a total effective radiation dose of around 145-205 mSv over five years. A 70-year-old exposed to 145 mSv has a lifetime attributable cancer risk of 0.42% (i.e., odds of 1 in 240). Similarly, for a total dose of 204 mSv, the risk would be 0.60% (1 in 170). The corresponding data for a 50-year-old would be 0.73% (1 in 140) and 1.03% (1 in 100), respectively. In high throughput units this could mean one cancer per year attributable to the EVAR programme. Of particular concern is the cumulative dose in those most sensitive to it; younger patients, smokers and women. Repeat exposure within short exposure intervals is particularly burdensome (e.g., planning CT followed by EVAR one week later and first surveillance CT at one month). Three alternatives reduce radiation exposure; reduction of the effective dose associated with each CT scan, reduction in the number of CT scans requested (or better temporal spacing of them) or replacement of CT with alternative modes of imaging/assessment.
Similar articles
-
Estimating the risk of solid organ malignancy in patients undergoing routine computed tomography scans after endovascular aneurysm repair.J Vasc Surg. 2012 Oct;56(4):929-37. doi: 10.1016/j.jvs.2012.02.061. Epub 2012 Jul 10. J Vasc Surg. 2012. PMID: 22784414
-
Radiation exposure in patients treated with endovascular aneurysm repair: what is the risk of cancer, and can we justify treating younger patients?Acta Radiol. 2017 Mar;58(3):323-330. doi: 10.1177/0284185116651002. Epub 2016 Jul 19. Acta Radiol. 2017. PMID: 27279268
-
The impact of radiation dose exposure during endovascular aneurysm repair on patient safety.J Vasc Surg. 2010 Aug;52(2):298-302. doi: 10.1016/j.jvs.2010.03.004. J Vasc Surg. 2010. PMID: 20670773
-
Is it time to eliminate CT after EVAR as routine follow-up?J Cardiovasc Surg (Torino). 2011 Apr;52(2):193-8. J Cardiovasc Surg (Torino). 2011. PMID: 21460769 Review.
-
Endovascular aneurysm repair: state-of-art imaging techniques for preoperative planning and surveillance.J Cardiovasc Surg (Torino). 2009 Aug;50(4):423-38. J Cardiovasc Surg (Torino). 2009. PMID: 19734828 Review.
Cited by
-
Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images.Br J Radiol. 2022 Sep 1;95(1138):20220378. doi: 10.1259/bjr.20220378. Epub 2022 Sep 8. Br J Radiol. 2022. PMID: 36039820 Free PMC article.
-
Review of Clinical Applications of Dual-Energy CT in Patients after Endovascular Aortic Repair.J Clin Med. 2023 Dec 18;12(24):7766. doi: 10.3390/jcm12247766. J Clin Med. 2023. PMID: 38137834 Free PMC article. Review.
-
Endovascular repair of abdominal aortic aneurysm does not improve early survival versus open repair in patients younger than 60 years.Eur J Vasc Endovasc Surg. 2012 May;43(5):506-12. doi: 10.1016/j.ejvs.2012.02.006. Epub 2012 Mar 3. Eur J Vasc Endovasc Surg. 2012. PMID: 22386386 Free PMC article.
-
Imaging in Interventional Radiology: Applications of Contrast-Enhanced Ultrasound.Semin Intervent Radiol. 2024 Aug 19;41(3):241-245. doi: 10.1055/s-0044-1787833. eCollection 2024 Jun. Semin Intervent Radiol. 2024. PMID: 39165654 Free PMC article. Review.
-
Implantable Pressure-Sensing Devices for Monitoring Abdominal Aortic Aneurysms in Post-Endovascular Aneurysm Repair.Sensors (Basel). 2024 May 30;24(11):3526. doi: 10.3390/s24113526. Sensors (Basel). 2024. PMID: 38894317 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical