Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT
- PMID: 20093602
- DOI: 10.2214/AJR.09.2583
Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT
Abstract
Objective: The purpose of this study was to investigate the accuracy and reproducibility of results acquired with computer-aided volumetry software during MDCT of pulmonary nodules exhibiting ground-glass opacity.
Materials and methods: To evaluate the accuracy of computer-aided volumetry software, we performed thin-section helical CT of a chest phantom that included simulated 3-, 5-, 8-, 10-, and 12-mm-diameter ground-glass opacity nodules with attenuation of -800, -630, and -450 HU. Three radiologists measured the volume of the nodules and calculated the relative volume measurement error, which was defined as follows: (measured nodule volume minus assumed nodule volume / assumed nodule volume) x 100. Two radiologists performed two independent measurements of 59 nodules in humans. Intraobserver and interobserver agreement was evaluated with Bland-Altman methods.
Results: The relative volume measurement error for simulated ground-glass opacity nodules measuring 3 mm ranged from 51.1% to 85.2% and for nodules measuring 5 mm or more in diameter ranged from -4.1% to 7.1%. In the clinical study, for intraobserver agreement, the 95% limits of agreement were -14.9% and -13.7% and -16.6% to 15.7% for observers A and B. For interobserver agreement, these values were -16.3% to 23.7% for nodules 8 mm in diameter or larger.
Conclusion: With computer-aided volumetry of ground-glass opacity nodules, the relative volume measurement error was small for nodules 5 mm in diameter or larger. Intraobserver and interobserver agreement was relatively high for nodules 8 mm in diameter or larger.
Similar articles
-
Volume-doubling time of pulmonary nodules with ground glass opacity at multidetector CT: Assessment with computer-aided three-dimensional volumetry.Acad Radiol. 2011 Jan;18(1):63-9. doi: 10.1016/j.acra.2010.08.022. Acad Radiol. 2011. PMID: 21145028
-
Pulmonary nodules with ground-glass opacity can be reliably measured with low-dose techniques regardless of iterative reconstruction: results of a phantom study.AJR Am J Roentgenol. 2015 Jun;204(6):1242-7. doi: 10.2214/AJR.14.13820. AJR Am J Roentgenol. 2015. PMID: 26001234
-
Detection of nodules showing ground-glass opacity in the lungs at low-dose multidetector computed tomography: phantom and clinical study.J Comput Assist Tomogr. 2009 Jan-Feb;33(1):49-53. doi: 10.1097/RCT.0b013e31815e6291. J Comput Assist Tomogr. 2009. PMID: 19188784
-
Use of Volumetry for Lung Nodule Management: Theory and Practice.Radiology. 2017 Sep;284(3):630-644. doi: 10.1148/radiol.2017151022. Radiology. 2017. PMID: 28825886 Review.
-
Pure ground-glass opacity neoplastic lung nodules: histopathology, imaging, and management.AJR Am J Roentgenol. 2014 Mar;202(3):W224-33. doi: 10.2214/AJR.13.11819. AJR Am J Roentgenol. 2014. PMID: 24555618 Review.
Cited by
-
Software performance in segmenting ground-glass and solid components of subsolid nodules in pulmonary adenocarcinomas.Eur Radiol. 2016 Dec;26(12):4465-4474. doi: 10.1007/s00330-016-4317-3. Epub 2016 Apr 5. Eur Radiol. 2016. PMID: 27048527
-
Analysis of CT morphologic features and attenuation for differentiating among transient lesions, atypical adenomatous hyperplasia, adenocarcinoma in situ, minimally invasive and invasive adenocarcinoma presenting as pure ground-glass nodules.Sci Rep. 2019 Oct 10;9(1):14586. doi: 10.1038/s41598-019-50989-1. Sci Rep. 2019. PMID: 31601919 Free PMC article.
-
Semi-automatic quantification of subsolid pulmonary nodules: comparison with manual measurements.PLoS One. 2013 Nov 21;8(11):e80249. doi: 10.1371/journal.pone.0080249. eCollection 2013. PLoS One. 2013. PMID: 24278264 Free PMC article.
-
Indeterminate pulmonary nodules: risk for having or for developing lung cancer?Cancer Prev Res (Phila). 2014 Dec;7(12):1173-8. doi: 10.1158/1940-6207.CAPR-14-0364. Epub 2014 Oct 27. Cancer Prev Res (Phila). 2014. PMID: 25348855 Free PMC article.
-
Total intracranial hemorrhage volume measurement summating all compartments best in traumatic and nontraumatic intracranial bleeding.Brain Behav. 2024 May;14(5):e3481. doi: 10.1002/brb3.3481. Brain Behav. 2024. PMID: 38680018 Free PMC article. Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources