Early development of pacemaker Reel syndrome in an elderly patient with cognitive impairment
- PMID: 20098044
Early development of pacemaker Reel syndrome in an elderly patient with cognitive impairment
Abstract
Reel syndrome is a rare form of Twiddler's syndrome and is characterized by rotation of permanent pacemaker on its transverse axis and rolling of the electrode around the generator. An 83-year-old man with severely impaired mental status, agitation, and uncontrolled movement of extremities underwent pacemaker implantation for symptomatic atrial fibrillation. The pacemaker generator was fixed to the pectoral fascia with nonabsorbable ligatures. On the next day, failure to capture the ventricle was noted. Fluoroscopic examination showed coiling of the electrode around the generator. During urgent intervention, the ligature of the generator was observed to be released from the pectoral fascia. The pacemaker lead was not damaged; therefore, the same lead was re-implanted, connected to the generator, and carefully fixed to the pectoral fascia. The patient showed rapid clinical improvement together with his mental status. No abnormality was detected during three months of follow-up. Patients with impaired consciousness, children, and older persons require a close follow-up because of their propensity to this serious and life-threatening complication.
Similar articles
-
Reel syndrome and pulsatile liver in a patient with a two-chamber pacemaker.Jpn Heart J. 2004 Nov;45(6):1037-42. doi: 10.1536/jhj.45.1037. Jpn Heart J. 2004. PMID: 15655279
-
Pacemaker twiddler's syndrome (rotation of the pacemaker around the electrode cable, a rare complication of pacemaker therapy).Acta Chir Hung. 1989;30(3):231-6. Acta Chir Hung. 1989. PMID: 2596244
-
[Extraction of infected pacemaker electrode using catheter and snare].Kyobu Geka. 1993 Oct;46(11):937-40. Kyobu Geka. 1993. PMID: 8230906 Japanese.
-
Extreme pacemaker reel syndrome in an elderly patient with cognitive impairment.Br J Nurs. 2020 Mar 26;29(6):353-357. doi: 10.12968/bjon.2020.29.6.353. Br J Nurs. 2020. PMID: 32207647 Review.
-
[Prevention of atrial fibrillation by atrial-based pacemaker implantation].Orv Hetil. 1999 Oct 24;140(43):2393-7. Orv Hetil. 1999. PMID: 10624110 Review. Hungarian.
Cited by
-
Alzheimer's disease: is pacemaker implantation safe?Am J Alzheimers Dis Other Demen. 2012 May;27(3):202-5. doi: 10.1177/1533317512444457. Epub 2012 Apr 20. Am J Alzheimers Dis Other Demen. 2012. PMID: 22523108 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical