. 2010 Feb;31(2):416-24.
doi: 10.1002/jmri.22046.

Visualization of deep veins and detection of deep vein thrombosis (DVT) with balanced turbo field echo (b-TFE) and contrast-enhanced T1 fast field echo (CE-FFE) using a blood pool agent (BPA)

Affiliations

Visualization of deep veins and detection of deep vein thrombosis (DVT) with balanced turbo field echo (b-TFE) and contrast-enhanced T1 fast field echo (CE-FFE) using a blood pool agent (BPA)

Tone Enden et al. J Magn Reson Imaging. 2010 Feb.

Abstract

Purpose: To assess image quality, vessel visualization, preliminary diagnostic properties, and interobserver variability of a novel balanced turbo field echo (b-TFE) sequence and contrast-enhanced T1 fast field echo (CE-FFE) sequence with blood pool agent (BPA).

Materials and methods: A total of 15 healthy volunteers and six patients with ultrasound-verified proximal deep vein thrombosis (DVT) were examined from the inferior vena cava (IVC) to the proximal calf veins.

Results: The great majority of deep veins were completely visualized on both sequences. In healthy volunteers the IVC was completely visualized in five b-TFE and 11 CE-FFE scans, and partially in seven b-TFE and four CE-FFE scans (P = 0.008). Poorest image quality was in the pelvis. Contrast-to-noise ratio (CNR) was higher on b-TFE compared to CE-FFE, with significant difference in calf images (P = 0.036). Sensitivity was 100% for proximal DVT with both methods. Specificity was 70% (CE-FFE) and 80% (b-TFE) for proximal femoral DVT; 100% in distal femoral. Interobserver reliability was kappa 1.0 (b-TFE), 0.9 (CE-FFE) for proximal, and overall poor for distal DVT.

Conclusion: Contrast-enhancement did not add valuable information in visualizing deep veins of the lower limbs compared to b-TFE, though the IVC was slightly better visualized. Diagnostic properties and interobserver reliability of both sequences were good for proximal DVT and poor for distal DVT.