Evaluation of aortic root and valve calcifications by multi-detector computed tomography
- PMID: 20099715
Evaluation of aortic root and valve calcifications by multi-detector computed tomography
Abstract
Background and aim of the study: In percutaneous aortic valve replacement (AVR), whilst calcifications are used as landmarks in fluoroscopic placement of the stent, they may also complicate stent placement. In response to this problem, the study aim was to examine severe aortic root calcification by using multi-detector computed tomography (MDCT), to better understand the pathology complicating percutaneous valve placement.
Methods: In 33 patients with severe aortic stenosis and scheduled for surgery, the 'inner orifice' and 'outer fibrous' annulus diameter and area (with and without calcification) were measured, in addition to the distances of the calcifications and coronary ostia from the annulus, using by ECG-gated 64-slice MDCT. Aortic root calcification was evaluated as minimal (< 25% of total circumference), mild (25-50%), moderate (50-75%), and severe (75-100%).
Results: The inner orifice annulus area was 5.9 +/- 1.9 cm2 (range: 1.4-10.1 cm2), while the outer fibrous area was 7.5 +/- 1.8 cm2 (range: 4.7-11.5 cm2). The proximal-to-distal extent of valve calcification from the annulus in the mid-center of leaflets was 0.8 +/- 0.26 cm. In 36% of patients, valvular calcification extended +/- 3 mm within the coronary-ostium level. The distance of the coronary ostia from the annulus was variable, with a mean of 1.3 +/- 0.35 cm (range: 0.6-2.4 cm) for the left coronary artery. In 42% of patients, a 'low coronary ostium' (< or = 1.1 cm), and in 6% a 'critical-low-coronary ostium' (< or = 8 mm) was identified. Annulus calcification was present in 100% of cases, but the severity varied widely (severe 50%, moderate 35%, mild 15%). In 36% of cases, the aortic annulus calcification extended caudally into the membranous part of the interventricular septum (and thus into the left ventricular outflow tract), and in 42% of cases (n = 14) into the anterior mitral valve leaflet.
Conclusion: The present results indicated that cardiac MDCT may qualify as a primary pre-procedural imaging modality to select patients for percutaneous AVR, based on the measurement and characterization of the aortic root and valve calcification. In comparison to echocardiography, CT will reduce--if not eliminate--difficulties in visualizing the aortic orifice area in heavily calcified valves. Furthermore, knowledge of the exact location of calcific deposits provides a distinct advantage to the fluroscopist for precise placement of the percutaneous aortic valve. Likewise, knowledge of the coronary arteries orifice in relation to the valve plane is critical to prevent inadvertent coronary artery occlusion, and would clearly be beneficial when planning future valve designs.
Similar articles
-
Noninvasive evaluation of the aortic root with multislice computed tomography implications for transcatheter aortic valve replacement.JACC Cardiovasc Imaging. 2008 May;1(3):321-30. doi: 10.1016/j.jcmg.2007.12.006. JACC Cardiovasc Imaging. 2008. PMID: 19356444
-
Extent and distribution of calcification of both the aortic annulus and the left ventricular outflow tract predict aortic regurgitation after transcatheter aortic valve replacement.EuroIntervention. 2014 Oct;10(6):732-8. doi: 10.4244/EIJV10I6A126. EuroIntervention. 2014. PMID: 25330505
-
Aortic annulus and root characteristics in severe aortic stenosis due to bicuspid aortic valve and tricuspid aortic valves: implications for transcatheter aortic valve therapies.Catheter Cardiovasc Interv. 2015 Aug;86(2):E88-98. doi: 10.1002/ccd.25948. Epub 2015 Apr 24. Catheter Cardiovasc Interv. 2015. PMID: 25914355
-
How valvular calcification can affect the outcomes of transcatheter aortic valve implantation.Expert Rev Med Devices. 2020 Aug;17(8):773-784. doi: 10.1080/17434440.2020.1789456. Epub 2020 Jul 13. Expert Rev Med Devices. 2020. PMID: 32597265 Review.
-
[Aortic valve stenosis: computed tomography prior to transcatheter aortic valve implantation (TAVI). How can the outcome be improved?].Herz. 2015 Jun;40(4):576-82. doi: 10.1007/s00059-015-4232-4. Herz. 2015. PMID: 25963033 Review. German.
Cited by
-
In vitro study of coronary flow occlusion in transcatheter aortic valve implantation.J Thorac Dis. 2014 Dec;6(12):1772-7. doi: 10.3978/j.issn.2072-1439.2014.12.19. J Thorac Dis. 2014. PMID: 25589972 Free PMC article.
-
Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis.Int J Cardiovasc Imaging. 2012 Feb;28(2):343-52. doi: 10.1007/s10554-010-9784-z. Epub 2011 Jan 30. Int J Cardiovasc Imaging. 2012. PMID: 21279693 Free PMC article.
-
Imaging of cardiac valves by computed tomography.Scientifica (Cairo). 2013;2013:270579. doi: 10.1155/2013/270579. Epub 2013 Dec 29. Scientifica (Cairo). 2013. PMID: 24490107 Free PMC article.
-
Aortic root evaluation prior to transcatheter aortic valve implantation-Correlation of manual and semi-automatic measurements.PLoS One. 2018 Jun 28;13(6):e0199732. doi: 10.1371/journal.pone.0199732. eCollection 2018. PLoS One. 2018. PMID: 29953507 Free PMC article.
-
Role of Echocardiography Before Transcatheter Aortic Valve Implantation (TAVI).Curr Cardiol Rep. 2016 Apr;18(4):38. doi: 10.1007/s11886-016-0715-z. Curr Cardiol Rep. 2016. PMID: 26960423 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Research Materials