Optimisation-based thermal treatment planning for catheter-based ultrasound hyperthermia
- PMID: 20100052
- DOI: 10.3109/02656730903341332
Optimisation-based thermal treatment planning for catheter-based ultrasound hyperthermia
Abstract
A patient-specific optimisation-based hyperthermia treatment planning program for catheter-based ultrasound technology was developed for a priori evaluation of proposed applicator implant strategies and determination of initial applied power settings. The interstitial and endocavity heating applicators, designed for delivering 3-D controllable hyperthermia within High Dose Rate (HDR) brachytherapy implants, consist of linear and sectored arrays of ultrasound transducers with variable power control in both length and angle. A 3D biothermal model, which incorporates relevant anatomical structures and implant geometries based upon HDR treatment planning, has been developed to simulate the temperature distributions induced by these ultrasound applicators within the catheter implants. A temperature-based constrained optimisation algorithm was devised and integrated within the finite-element thermal solver to determine the optimal applied power levels. A temperature-expressed objective function and constraints were employed to limit maximum temperature (T(max)), maximise target coverage (T(target)), and minimise thermal exposure to normal tissue and surrounding organs. The optimisation-based treatment planning was applied on representative examples of clinical HDR implants for endocavity treatment of cervix (n = 3) and interstitial treatment of prostate (n = 3). Applicator positioning and orientation, T(max), and T(target), were varied, and temperature volume and thermal dose volume histograms calculated for each plan. The optimisation approach provided optimal applied power levels (4-24 independent transducer sections) leading to conforming or tailored temperature distributions for all cases, as indicated with improved temperature index T(90) in the target volume and negligible temperature and thermal dose (t(43,max) < 1 min) exposure in surrounding non-targeted tissues, such as bladder and rectum. The precision of the optimised power estimates was shown to be within <5% for a range of starting levels and were similarly convergent. The execution times of this optimisation (<16 min) and forward thermal treatment planning (<22 min) is sufficiently fast to be integrated into the clinical setting. This optimisation-based treatment planning platform for catheter-based ultrasound applicators is a useful tool to provide feedback for applicator selection (sector angle, number of transducer sections along length), positioning (angle or orientation), optimal initial power settings, and has potential to significantly improve the delivery of hyperthermia in conjunction with HDR brachytherapy.
Similar articles
-
Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer.Phys Med Biol. 2011 Jul 7;56(13):3967-84. doi: 10.1088/0031-9155/56/13/014. Epub 2011 Jun 10. Phys Med Biol. 2011. PMID: 21666290
-
Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma.Med Phys. 2011 Feb;38(2):598-611. doi: 10.1118/1.3512803. Med Phys. 2011. PMID: 21452697 Free PMC article.
-
Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators.Phys Med Biol. 2005 Nov 7;50(21):4957-75. doi: 10.1088/0031-9155/50/21/001. Epub 2005 Oct 12. Phys Med Biol. 2005. PMID: 16237234
-
Catheter-based ultrasound applicators for selective thermal ablation: progress towards MRI-guided applications in prostate.Int J Hyperthermia. 2004 Nov;20(7):739-56. doi: 10.1080/02656730410001721816. Int J Hyperthermia. 2004. PMID: 15675669 Review.
-
Thermal ablation and high-temperature thermal therapy: overview of technology and clinical implementation.Int J Hyperthermia. 2005 Dec;21(8):745-53. doi: 10.1080/02656730500271692. Int J Hyperthermia. 2005. PMID: 16338857 Review.
Cited by
-
Thermal therapy of pancreatic tumours using endoluminal ultrasound: Parametric and patient-specific modelling.Int J Hyperthermia. 2016;32(2):97-111. doi: 10.3109/02656736.2015.1119892. Epub 2016 Jan 21. Int J Hyperthermia. 2016. PMID: 27097663 Free PMC article.
-
Treatment Planning Strategies for Interstitial Ultrasound Ablation of Prostate Cancer.IEEE Open J Eng Med Biol. 2024 May 8;5:362-375. doi: 10.1109/OJEMB.2024.3397965. eCollection 2024. IEEE Open J Eng Med Biol. 2024. PMID: 38899026 Free PMC article.
-
Simulation techniques in hyperthermia treatment planning.Int J Hyperthermia. 2013 Jun;29(4):346-57. doi: 10.3109/02656736.2013.790092. Epub 2013 May 14. Int J Hyperthermia. 2013. PMID: 23672453 Free PMC article. Review.
-
Utility of treatment planning for thermochemotherapy treatment of nonmuscle invasive bladder carcinoma.Med Phys. 2012 Mar;39(3):1170-81. doi: 10.1118/1.3679839. Med Phys. 2012. PMID: 22380348 Free PMC article.
-
Theoretical investigation of transgastric and intraductal approaches for ultrasound-based thermal therapy of the pancreas.J Ther Ultrasound. 2017 May 3;5:10. doi: 10.1186/s40349-017-0090-2. eCollection 2017. J Ther Ultrasound. 2017. PMID: 28469915 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources