Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years
- PMID: 20103205
- DOI: 10.1016/j.athoracsur.2009.08.070
Effect of prosthesis-patient mismatch on long-term survival with aortic valve replacement: assessment to 15 years
Abstract
Background: The effect of prosthesis-patient mismatch on long-term survival after aortic valve replacement has received considerable attention but there remains controversy. This study was performed to determine the predictors of mortality after aortic valve replacement and influence of prosthesis-patient mismatch on survival.
Methods: Contemporary mechanical prostheses and bioprostheses were implanted in 3,343 patients with aortic valve replacement between 1982 and 2003. The mean age was 68.06 +/- 11.20 years (median 70.06; range, 19 to 94), and the mean follow-up was 6.18 +/- 4.96 years, for a total of 20,666 years of follow-up. Prosthesis-patient mismatch was classified by effective orifice area index categories: normal (> 0.85 cm(2)/m(2)), 1,547 (46.3%); mild-to-moderate (> 0.65 cm(2)/m(2) to < or = 0.85 cm(2)/m(2)), 1,584 (47.4%); and severe (< 0.65 cm(2)/m(2)), 212 (6.3%).
Results: The predictors of overall mortality were age, age categorization, New York Heart Association functional class III/IV, concomitant coronary artery bypass graft surgery, prosthesis type, preoperative congestive heart failure, diabetes mellitus, renal failure, and chronic obstructive pulmonary disease. All categories of effective orifice area indexes were not predictive of overall mortality, late mortality, or early mortality. The 15-year overall survival was differentiated by effective orifice area index categories: 38.1% +/- 2.1%, 37.0% +/- 2.2%, and 22.1% +/- 6.5%, respectively, for the three categories. Survival adjusted for the covariates (effective orifice area index, age, basal mass index, and ejection fraction) determined no effect except severe effective orifice area index when adjusted for ejection fraction more than 50% (p = 0.049).
Conclusions: Prosthesis-patient mismatch is not a predictor of overall standard unadjusted mortality to 15 years after aortic valve replacement, regardless of the category of effective orifice area index.
2010 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Effect of prosthesis-patient mismatch on long-term survival with mitral valve replacement: assessment to 15 years.Ann Thorac Surg. 2009 Apr;87(4):1135-41; discussion 1142. doi: 10.1016/j.athoracsur.2009.01.056. Ann Thorac Surg. 2009. PMID: 19324139
-
Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves.J Thorac Cardiovasc Surg. 2004 Jan;127(1):149-59. doi: 10.1016/j.jtcvs.2003.07.043. J Thorac Cardiovasc Surg. 2004. PMID: 14752425
-
Influence of prosthesis-patient mismatch on diastolic heart failure after aortic valve replacement.Ann Thorac Surg. 2008 Apr;85(4):1310-7. doi: 10.1016/j.athoracsur.2007.12.069. Ann Thorac Surg. 2008. PMID: 18355517
-
Mitroflow aortic pericardial bioprosthesis--clinical performance.Eur J Cardiothorac Surg. 2009 Nov;36(5):818-24. doi: 10.1016/j.ejcts.2009.05.020. Epub 2009 Aug 22. Eur J Cardiothorac Surg. 2009. PMID: 19700338 Review.
-
Is patient-prosthesis mismatch an independent risk factor for early and mid-term overall mortality in adult patients undergoing aortic valve replacement?Interact Cardiovasc Thorac Surg. 2009 Sep;9(3):510-8. doi: 10.1510/icvts.2009.207597. Epub 2009 Jun 4. Interact Cardiovasc Thorac Surg. 2009. PMID: 19497953 Review.
Cited by
-
Trends in mechanical aortic valve replacement surgery in a large, multi-surgeon, single hospital practice.Kardiochir Torakochirurgia Pol. 2014 Dec;11(4):367-72. doi: 10.5114/kitp.2014.47334. Epub 2014 Nov 30. Kardiochir Torakochirurgia Pol. 2014. PMID: 26336451 Free PMC article.
-
Safety, effectiveness and haemodynamic performance of a new stented aortic valve bioprosthesis.Eur J Cardiothorac Surg. 2017 Sep 1;52(3):425-431. doi: 10.1093/ejcts/ezx066. Eur J Cardiothorac Surg. 2017. PMID: 28475690 Free PMC article. Clinical Trial.
-
Patient-prosthesis mismatch in patients with aortic valve replacement.Gen Thorac Cardiovasc Surg. 2013 May;61(5):274-9. doi: 10.1007/s11748-013-0216-6. Epub 2013 Feb 13. Gen Thorac Cardiovasc Surg. 2013. PMID: 23404312 Free PMC article.
-
Prosthesis-patient mismatch in aortic stenosis.Gen Thorac Cardiovasc Surg. 2014 Feb;62(2):78-86. doi: 10.1007/s11748-013-0331-4. Epub 2013 Oct 17. Gen Thorac Cardiovasc Surg. 2014. PMID: 24132681 Review.
-
Moderate Patient-Prosthesis Mismatch Has No Negative Effect on Patients' Functional Status After Aortic Valve Replacement With CarboMedics Prosthesis.Res Cardiovasc Med. 2016 Mar 5;5(2):e29038. doi: 10.5812/cardiovascmed.29038. eCollection 2016 May. Res Cardiovasc Med. 2016. PMID: 26949687 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical