Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC
- PMID: 20109284
- DOI: 10.1093/chromsci/48.2.95
Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC
Abstract
A micellar electrokinetic capillary chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations. The influence of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, capillary temperature, applied voltage, and injection time was investigated, and the method validation studies were performed. The optimum separation for these analytes was achieved in less than 10 min at 30 degrees C with a fused-silica capillary column (56 cm x 50 microm i.d.) and a 25mM borate buffer at pH 9.0 containing 25mM SDS and 10% (v/v) acetonitrile. The samples were injected hydrodynamically for 3 s at 50 mbar, and the applied voltage was +30.0 kV. Detection wavelength was set at 238 nm. Diflunisal was used as internal standard. The method was suitably validated with respect to stability, specificity, linearity, limits of detection and quantification, accuracy, precision, and robustness. The limits of detection and quantification were 1.0 and 2.0 microg/mL for both ezetimibe and simvastatin, respectively. The method developed was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations.
Similar articles
-
Development and validation of a stability-indicating micellar electrokinetic chromatography method for the determination of ezetimibe in pharmaceutical formulations.Anal Sci. 2008 Apr;24(4):499-503. doi: 10.2116/analsci.24.499. Anal Sci. 2008. PMID: 18403842
-
Determination of piribedil in pharmaceutical formulations by micellar electrokinetic capillary chromatography.Anal Bioanal Chem. 2004 May;379(2):308-11. doi: 10.1007/s00216-004-2539-8. Epub 2004 Feb 20. Anal Bioanal Chem. 2004. PMID: 14985904
-
Simultaneous liquid chromatographic determination of ezetimibe and simvastatin in pharmaceutical products.J AOAC Int. 2007 Nov-Dec;90(6):1566-72. J AOAC Int. 2007. PMID: 18193733
-
Validation of a rapid micellar electrokinetic capillary chromatographic method for the simultaneous determination of isoniazid and pyridoxine hydrochloride in pharmaceutical formulation.J Chromatogr B Analyt Technol Biomed Life Sci. 2007 Jul 1;854(1-2):35-42. doi: 10.1016/j.jchromb.2007.03.050. Epub 2007 Apr 12. J Chromatogr B Analyt Technol Biomed Life Sci. 2007. PMID: 17481971
-
Capillary electrophoresis as a versatile tool for the bioanalysis of drugs--a review.J Pharm Biomed Anal. 1999 Sep;20(6):831-63. doi: 10.1016/s0731-7085(99)00088-6. J Pharm Biomed Anal. 1999. PMID: 10746954 Review.
Cited by
-
Bi-functionalization of a calcium phosphate-coated titanium surface with slow-release simvastatin and metronidazole to provide antibacterial activities and pro-osteodifferentiation capabilities.PLoS One. 2014 May 20;9(5):e97741. doi: 10.1371/journal.pone.0097741. eCollection 2014. PLoS One. 2014. PMID: 24844416 Free PMC article.
-