Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Feb 15;35(4):371-7.
doi: 10.1097/BRS.0b013e3181b962a4.

The effect of two clinically relevant fusionless scoliosis implant strategies on the health of the intervertebral disc: analysis in an immature goat model

Affiliations

The effect of two clinically relevant fusionless scoliosis implant strategies on the health of the intervertebral disc: analysis in an immature goat model

Kenneth J Hunt et al. Spine (Phila Pa 1976). .

Abstract

Study design: Immature goat spines were instrumented at 5 levels with 2 different fusionless scoliosis implants. Instrumented and subadjacent spinal segments were analyzed to determine the effect on the disc and endplate.

Objective: Analyze the regional biochemistry and histology of spinal motion segments in healthy goat spines treated with 2 clinically relevant, fusionless scoliosis implants.

Summary of background data: Fusionless scoliosis surgery is thought to be more physiologic than fusion as it preserves the growth, motion, and function of the spine. There are presently little data supporting this belief.

Methods: Scoliosis was created in twelve 8-week-old female goats (n = 6 per group) using 1 of 2 fusionless scoliosis implant strategies: 2 SMA staples per level or a bone anchor/ligament tether. A third group served as controls (n = 6). Goats were analyzed after 6 months. Qualitative and quantitative analyses were performed on spinal motion segments using H&E, TUNEL, and caspase-3 staining.

Results: Neither implant strategy produced degenerative changes in the disc. However, discs at instrumented levels in both groups demonstrated decreased cell density (P < 0.01) and increased cellular apoptosis (P < 0.001) compared to controls. Subadjacent discs demonstrated preservation of viable cells and endplate vascularity compared to instrumented discs.

Conclusion: Fusionless scoliosis implants result in alterations in viable cell density within the disc and reduced vascularity in the vertebral endplates of instrumented but not subadjacent discs. Though obvious disc degeneration was not observed, the implications of the cellular and histologic changes are not known. Additional study will be necessary to better understand various fusionless scoliosis surgery strategies and their effect on surrounding tissues.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms