Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Feb;68(2):363-71.
doi: 10.1016/j.joms.2009.09.086. Epub 2010 Jan 15.

Three-dimensional computed tomographic analysis of airway anatomy

Affiliations
Comparative Study

Three-dimensional computed tomographic analysis of airway anatomy

Zachary R Abramson et al. J Oral Maxillofac Surg. 2010 Feb.

Abstract

Purpose: To test the reliability of a 3-dimensional computed tomographic (3D-CT) analysis of airway size and shape and to correlate the 3D-CT findings with lateral cephalometric measurements.

Materials and methods: Fifteen pairs of preoperative maxillofacial 3D-CT scans and digital lateral cephalograms of patients treated for obstructive sleep apnea were used in the present study. Digital 3D-CT reconstructions were created and 12 measurements of airway size and 4 of shape were analyzed. The posterior airway space (PAS), middle airway space, and hyoid to mandibular plane distances were measured on the cephalograms. We then randomly selected 5 CT scans and 5 cephalograms which were analyzed blindly on 5 separate occasions by 2 investigators (Z.A., J.T.) to establish the intraclass correlation coefficients for inter- and intraexaminer reliability. All 15 pairs of images were used to compute the Pearson correlation coefficients to establish the relationship between the CT and cephalometric measurements.

Results: The intra- and interexaminer reliabilities were high for all CT (0.86 to 1.0 and 0.89 to 1.0, respectively; P < .001) and cephalometric measurements (0.84 to 1.0 and 0.91 to 0.99, respectively; P < .001). The CT measurements retroglossal anteroposterior dimension and distance between the genial tubercle and hyoid exhibited a positive correlation with the PAS (r = .60, P = 02 and r = .54, P = .04, respectively), and the lateral/anteroposterior dimension demonstrated an inverse correlation (r = -.68, P = .01) with the PAS.

Conclusion: The results of the present study indicate that the 3D-CT and lateral cephalometric measurements we selected are reliable and reproducible. The only cephalometric measurement that exhibited any correlation with the CT parameters was PAS.