Significance of the subvalvular apparatus for left-ventricular dimensions and systolic function: experimental replacement of the mitral valve
- PMID: 2011848
- DOI: 10.1055/s-2007-1013922
Significance of the subvalvular apparatus for left-ventricular dimensions and systolic function: experimental replacement of the mitral valve
Abstract
To study the significance of the subvalvular apparatus for left-ventricular performance in mitral valve replacement, a new experimental model was developed. In 21 dogs St. Jude prostheses were implanted in the mitral position preserving the chordae tendineae and the papillary muscles by plicating and fixing the mitral leaflets with the prosthesis on the valvular annulus. Flexible steel wires were slung around the chordae tendineae of the anterior and the posterior papillary muscle separately and passed through the left ventricular wall via insulating plastic cannulas. Left-ventricular dimensions and global systolic function were measured during volume loading with blood before and after severance of the chordae tendineae by external application of electrocautery to the steel wires. Thus the heart continued beating without any interference following loss of the subvalvular apparatus. The external left ventricular diameters in the major and minor axis were determined by sonomicrometry. Left-ventricular systolic and diastolic pressures were measured by catheter tip manometers, stroke volume by electromagnetic measurements of flow in the ascending aorta. When the chordae tendineae had been cut, left-ventricular end-diastolic diameters in the major axis were increased ( + 2%), in the minor axis decreased (-1%) at any left-ventricular end-diastolic pressure. Systolic shortening of the major axis diameter was considerably reduced (20-27%) at any left-ventricular end-diastolic pressure following severance of the chordae tendineae. Significant increase of the systolic shortening in the minor axis diameter occurred at preload levels of 3-6 mmHg (15-8%), while at higher left-ventricular end-diastolic pressure of 7-8 mmHg no significant changes were present.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
[Experimental principles for preserving annulo-ventricular integrity of the mitral valve].Herz. 1996 Jun;21(3):144-58. Herz. 1996. PMID: 8767857 German.
-
Importance of the mitral apparatus for left ventricular function: an experimental approach.Eur J Cardiothorac Surg. 1992;6 Suppl 1:S17-23; discussion S24. Eur J Cardiothorac Surg. 1992. PMID: 1389273
-
Importance of the left ventricular subvalvular apparatus for cardiac performance.J Heart Valve Dis. 1993 Nov;2(6):642-5. J Heart Valve Dis. 1993. PMID: 7719504
-
[Acute mitral valve insufficiency].Ann Cardiol Angeiol (Paris). 1995 Dec;44(10):561-6. Ann Cardiol Angeiol (Paris). 1995. PMID: 8787332 Review. French.
-
Role of the mitral subvalvular apparatus in left ventricular systolic mechanics.Semin Thorac Cardiovasc Surg. 1989 Oct;1(2):133-43. Semin Thorac Cardiovasc Surg. 1989. PMID: 2488417 Review. No abstract available.
Cited by
-
The Impact of Sub-valvular Apparatus Preservation on Prosthetic Valve Dysfunction During Mitral Valve Replacement.Res Cardiovasc Med. 2013 Feb;2(1):55-61. doi: 10.5812/cardiovascmed.8054. Epub 2013 Feb 24. Res Cardiovasc Med. 2013. PMID: 25478491 Free PMC article.
-
The mechanobiology of mitral valve function, degeneration, and repair.J Vet Cardiol. 2012 Mar;14(1):47-58. doi: 10.1016/j.jvc.2012.01.002. Epub 2012 Feb 25. J Vet Cardiol. 2012. PMID: 22366572 Free PMC article. Review.
MeSH terms
LinkOut - more resources
Full Text Sources