Computer-aided detection of acute pulmonary embolism with 64-slice multi-detector row computed tomography: impact of the scanning conditions and overall image quality in the detection of peripheral clots
- PMID: 20118717
- DOI: 10.1097/RCT.0b013e3181b2e383
Computer-aided detection of acute pulmonary embolism with 64-slice multi-detector row computed tomography: impact of the scanning conditions and overall image quality in the detection of peripheral clots
Abstract
Purpose: To evaluate the performance of a computer-aided detection (CAD) system for diagnosing peripheral acute pulmonary embolism (PE) with a 64-slice multi-detector row computed tomography (CT).
Materials and methods: Two radiologists investigated the accuracy of a software aimed at detecting peripheral clots (PECAD prototype, version 7; Siemens Medical Systems, Forchheim, Germany) by applying this tool for the analysis of the pulmonary arterial bed of 74 CT angiograms obtained with 64-slice dual-source CT (Definition; Siemens Medical Systems). These cases were retrospectively selected from a database of CT studies performed on the same CT unit, with a similar collimation (64 x 0.6 mm) and similar injection protocols. Patient selection was based on a variety of (1) scanning conditions, namely, nongated (n = 30), electrocardiography-gated (n = 30), and dual-energy CT angiograms (n = 14), and (2) image quality (IQ), namely, scans of excellent IQ (n = 53) and lower IQ due to lower levels of arterial enhancement and/or presence of noise (n = 21). The standard of truth was based on the 2 radiologists' consensus reading and the results of CAD.
Results: The software detected 80 of 93 peripheral clots present in the 21 patients (42 segmental and 38 subsegmental clots). The overall sensitivity (95% confidence interval) of the CAD tool was 86% (77%-92%) for detecting peripheral clots, 78% (64.5%-88%) at the segmental level and 97% (85.5%-99.9%) at the subsegmental level. Assuming normal vascular anatomy with 20 segmental and 40 subsegmental arteries, overall specificity and positive and negative predictive values (95% confidence interval) of the software were 91.8% (91%-92.6%), 18.4% (15%-22.4%), and 99.7% (99.5%-99.8%), respectively. A mean of 5.4 false positives was found per patient (total, 354 false positives), mainly linked to the presence of perivascular connective tissue (n = 119; 34%) and perivascular airspace consolidation (n = 97; 27%). The sensitivities (95% confidence interval) for the CAD tool were 91% (69.8%-99.3%) for dual-energy, 87% (59.3%-93.2%) for electrocardiography-gated, and 87% (73.5%-95.3%) for nongated scans (P > 0.05). No significant difference was found in the sensitivity of the CAD software when comparing the scans according to the scanning conditions and image quality.
Conclusions: The evaluated CAD software has a good sensitivity in detecting peripheral PE, which is not influenced by the scanning conditions or the overall image quality.
Similar articles
-
Acute pulmonary embolism: effect of a computer-assisted detection prototype on diagnosis--an observer study.Radiology. 2012 Jan;262(1):305-13. doi: 10.1148/radiol.11110372. Radiology. 2012. PMID: 22190659
-
Lung perfusion with dual-energy multidetector-row CT (MDCT): feasibility for the evaluation of acute pulmonary embolism in 117 consecutive patients.Acad Radiol. 2008 Dec;15(12):1494-504. doi: 10.1016/j.acra.2008.05.018. Acad Radiol. 2008. PMID: 19000866
-
The use of computer-aided detection for the assessment of pulmonary arterial filling defects at computed tomographic angiography.J Comput Assist Tomogr. 2008 Nov-Dec;32(6):913-8. doi: 10.1097/RCT.0b013e31815b3ed0. J Comput Assist Tomogr. 2008. PMID: 19204454
-
Acute pulmonary embolism.Radiol Clin North Am. 2010 Jan;48(1):31-50. doi: 10.1016/j.rcl.2009.10.002. Radiol Clin North Am. 2010. PMID: 19995628 Review.
-
[Value of multislice CT for the work-up of pulmonary embolism].Radiologe. 2007 Aug;47(8):685-90. doi: 10.1007/s00117-007-1533-5. Radiologe. 2007. PMID: 17624508 Review. German.
Cited by
-
[Computer-assisted diagnostic procedure for multislice computed tomography for assessment of the pulmonary arterial circulation. Clinical relevance].Radiologe. 2012 Apr;52(4):366-72. doi: 10.1007/s00117-012-2304-5. Radiologe. 2012. PMID: 22526116 German.
-
Stand-alone performance of a computer-assisted detection prototype for detection of acute pulmonary embolism: a multi-institutional comparison.Br J Radiol. 2012 Jun;85(1014):758-64. doi: 10.1259/bjr/26769569. Epub 2011 Dec 13. Br J Radiol. 2012. PMID: 22167514 Free PMC article.
-
Pixel-level annotated dataset of computed tomography angiography images of acute pulmonary embolism.Sci Data. 2023 Aug 4;10(1):518. doi: 10.1038/s41597-023-02374-x. Sci Data. 2023. PMID: 37542053 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous