Comparison of intravascular ultrasound, external ultrasound and digital angiography for evaluation of peripheral artery dimensions and morphology
- PMID: 2011983
- DOI: 10.1016/0002-9149(91)90613-p
Comparison of intravascular ultrasound, external ultrasound and digital angiography for evaluation of peripheral artery dimensions and morphology
Abstract
Validation of catheter-based intravascular ultrasound imaging has been based on comparisons with histology and digital angiography, each of which may have limitations in the assessment of arterial size and morphology. External, high-frequency ultrasound can accurately determine vessel dimensions and morphology and because, like ultravascular ultrasound, it also provides cross-sectional arterial ultrasound images, it may be a more appropriate technique for the in vivo comparison of arterial dimensions and morphology determined by intravascular ultrasound. Thus, intravascular ultrasound, external 2-dimensional ultrasound, Doppler color-flow imaging and digital angiography were compared for assessment of arterial dimensions and wall morphology at 29 femoral artery sites in 15 patients. Intravascular ultrasound and the other 3 imaging modalities correlated well in determination of lumen diameter (2-dimensional, r = 0.98, standard error of the estimate [SEE] = 0.14; Doppler color flow, r = 0.91, SEE = 1.11; angiography, r = 0.95, SEE = 0.91) and cross-sectional area (2-dimensional, r = 0.97, SEE = 0.04; Doppler color flow, r = 0.92, SEE = 0.14; angiography, r = 0.96, SEE = 0.08). However, lumen size measured by Doppler color flow was consistently smaller than that measured by the other 3 imaging modalities. Intravascular ultrasound detected arterial plaque at 15 sites, 5 of which were hypoechoic (soft) and 10 hyperechoic with distal shadowing (hard). Plaque was identified at 12 of 15 sites by Z-dimensional imaging (p = 0.30 vs intravascular ultrasound), but at only 6 of 15 sites by angiography (p = 0.003 vs intravascular ultrasound), only 1 of which was thought to be calcified plaque.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Intravascular ultrasonography versus digital subtraction angiography: a human in vivo comparison of vessel size and morphology.J Am Coll Cardiol. 1990 Sep;16(3):633-6. doi: 10.1016/0735-1097(90)90354-r. J Am Coll Cardiol. 1990. PMID: 2201712
-
Real-time assessment of experimental arterial angioplasty with transvenous intravascular ultrasound.J Am Coll Cardiol. 1992 Jan;19(1):217-22. doi: 10.1016/0735-1097(92)90075-x. J Am Coll Cardiol. 1992. PMID: 1530853
-
Intravascular ultrasound imaging: in vivo peripheral and coronary artery studies.Am J Card Imaging. 1991 Mar;5(1):60-4. Am J Card Imaging. 1991. PMID: 10147586
-
Virtual histology and color flow intravascular ultrasound in peripheral interventions.Semin Vasc Surg. 2006 Sep;19(3):155-62. doi: 10.1053/j.semvascsurg.2006.06.001. Semin Vasc Surg. 2006. PMID: 16996418 Review.
-
[New methods of coronary imaging II. Intracoronary ultrasonography in clinical practice].Ital Heart J Suppl. 2001 Jun;2(6):579-92. Ital Heart J Suppl. 2001. PMID: 11460831 Review. Italian.
Cited by
-
Magnetic resonance angiography of intravascular endoprostheses: investigation of three devices.Cardiovasc Intervent Radiol. 1995 Nov-Dec;18(6):360-6. doi: 10.1007/BF00338302. Cardiovasc Intervent Radiol. 1995. PMID: 8591621
-
In vivo and in vitro measurements of pulmonary arterial stiffness: A brief review.Pulm Circ. 2012 Oct;2(4):505-17. doi: 10.4103/2045-8932.105040. Pulm Circ. 2012. PMID: 23372936 Free PMC article.
-
Quantitative assessment of peripheral and coronary artery lesions before and after balloon angioplasty: a comparison of intravascular ultrasound and angiography.Heart Vessels. 1994;9(4):202-9. doi: 10.1007/BF01746065. Heart Vessels. 1994. PMID: 7961298
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources