Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2010 Jan;31(3):471-82.
doi: 10.1002/elps.200900286.

High-abundance protein depletion: comparison of methods for human plasma biomarker discovery

Affiliations
Comparative Study

High-abundance protein depletion: comparison of methods for human plasma biomarker discovery

Veronika Polaskova et al. Electrophoresis. 2010 Jan.

Abstract

Affinity depletion of abundant proteins from human plasma has become a routine sample preparation strategy in proteomics used prior to protein identification and quantitation. To date, there have been limited published studies comparing the performance of commercially available depletion products. We conducted a thorough evaluation of six depletion columns using 2-DE combined with sophisticated image analysis software, examining the following criteria: (i) efficiency of high-abundance protein depletion, (ii) non-specific removal of other than the targeted proteins and (iii) total number of protein spots detected on the gels following depletion. From all the products investigated, the Seppro IgY system provided the best results. It displayed the greatest number of protein spots on the depleted plasma gels, minimal non-specific binding and high efficiency of abundant protein removal. Nevertheless, the increase in the number of detected spots compared with the second best performing and cheaper multiple affinity removal column (MARC) was not shown to be statistically significant. The ProteoPrep spin column, considered to be the "deepest" depletion technique available at the time of conducting the study, surprisingly displayed significantly fewer spots on the flow-through fraction gels compared with both the Seppro and the MARC. The spin column format and low plasma capacity were also found to be impractical for 2-DE. To conclude, we succeeded in providing an overview of the depletion columns performances with regard to the three examined areas. Our study will serve as a reference to other scientists when deciding on the optimal product for their particular projects.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources