. 2010 Feb;11(1):26-31.
doi: 10.1007/BF03262706.

Microleakage of three different sealants on sound and questionable occlusal surfaces of permanent molars: an in vitro study

Affiliations

Microleakage of three different sealants on sound and questionable occlusal surfaces of permanent molars: an in vitro study

M G Michalaki et al. Eur Arch Paediatr Dent. 2010 Feb.

Abstract

Aim: This was to evaluate the microleakage of 3 different sealants, applied on sound and questionably carious occlusal surfaces with and without a bonding agent.

Methods: A total of 120 human molars were selected, photographed with a digital video microscope, and assigned by 3 independent examiners, according to the criteria of ICDAS II, in 2 groups of 60 teeth each. Group A: teeth with deep, clear, sound occlusal surfaces (ICDAS II, code 0). Group B: teeth with questionable occlusal surfaces, having deep, stained pits and fissures with probable incipient, but non-cavitated carious lesions (ICDAS II, codes 1 and 2). Each group was divided into 2 subgroups of 30 teeth each (bonding or no bonding) and then into 3 subgroups of 10 teeth each according to the type of sealant used: one conventional (Conseal) and 2 fluoridated (Conseal F and Teethmate F). After the application of the bonding agent and the sealant to the appropriate teeth, all specimens were subjected to thermal cycling and immersed in a 10% methylene blue dye solution for 4 hours. Average and summed microleakage for each sample were estimated from dye penetration scores on 3 mesiodistal sections of the tooth across the sealed occlusal surface. Non-parametric Friedman's 2-way ANOVA by ranks and Conover-Inman pair wise comparisons were used for differences at the 0.05 level of significance.

Results: According to Friedman's 2-way ANOVA by ranks analysis, although there were no significant differences between the different sealants (chi(2) = 0.048, df = 2, P = .976), there were significant differences between the sound and questionably carious occlusal surfaces (chi(2) = 24, df = 3, P = .000). Conover- Inman pair wise comparisons showed no differences between the groups using and not using bonding agents, on sound (SNB-SWB, P = .4561) or questionable occlusal surfaces (QNB-QWB, P = .0842).

Conclusions: Sealant microleakage on questionably carious occlusal surfaces was statistically significantly higher than that of sound occlusal surfaces. Using a bonding agent or fluoridated FS did not influence microleakage significantly, either on sound or on questionable fissured surfaces.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Public Health Dent. 2005 Spring;65(2):82-9 - PubMed
    1. Pediatr Dent. 2003 Sep-Oct;25(5):505-11 - PubMed
    1. Oper Dent. 2003 Jul-Aug;28(4):403-14 - PubMed
    1. J Am Dent Assoc. 2001 Jun;132(6):762-9 - PubMed
    1. J Dent Res. 1989 May;68(5):773-9 - PubMed

LinkOut - more resources