Long-term clinical and economic analysis of the Endeavor drug-eluting stent versus the Driver bare-metal stent: 4-year results from the ENDEAVOR II trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions)
- PMID: 20129543
- DOI: 10.1016/j.jcin.2009.10.011
Long-term clinical and economic analysis of the Endeavor drug-eluting stent versus the Driver bare-metal stent: 4-year results from the ENDEAVOR II trial (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions)
Abstract
Objectives: This study was designed to evaluate long-term clinical and economic outcomes for subjects receiving Endeavor drug-eluting versus Driver bare-metal stents (both Medtronic CardioVascular, Santa Rosa, California).
Background: Early studies found that the drug-eluting stent (DES) was a clinically and economically attractive alternative to the bare-metal stent; however, associations between DES and very late stent thrombosis suggest that longer follow-up is required.
Methods: We used clinical, resource use and follow-up data from 1,197 subjects randomized to receive Endeavor (n = 598) versus Driver (n = 599) stents in ENDEAVOR II (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions) study with Medicare cost weights and quality of life adjustments applied from secondary sources. We compared differences through 4-year follow-up (1,440 days).
Results: Patients in both treatment groups had similar baseline characteristics. The use of Endeavor versus Driver reduced 4-year target vessel revascularization rates per 100 subjects (10.4 vs. 21.5; difference: -11.1; 95% confidence interval [CI]: -16.0 to -6.1; p < 0.001), with no difference in the rates per 100 subjects of death (5.0 vs. 5.2; difference: -0.2; 95% CI: -2.7 to 2.4; p = 0.90) or nonfatal myocardial infarction (3.2 vs. 4.4; difference: -1.2; 95% CI: -3.4 to 1.0; p = 0.29). After discounting at a 3% annual rate, there were no differences in quality-adjusted survival days (1,093 vs. 1,090; difference: 3; 95% CI: -13 to 19; p = 0.69) and total medical costs ($21,483 vs. $21,680; difference: -$198; 95% CI: -$1,608 to $1,207; p = 0.78).
Conclusions: The use of Endeavor versus Driver was associated with a significant reduction in target vessel revascularization through 4-year follow-up with no difference in death, nonfatal myocardial infarction, quality-adjusted survival, or total medical costs. These results are comparable to those for other studies evaluating drug-eluting versus bare-metal stents. (Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions [ENDEAVOR II]; NCT00614848).
Comment in
-
Drug-eluting stents: more dollars than sense?JACC Cardiovasc Interv. 2009 Dec;2(12):1188-9. doi: 10.1016/j.jcin.2009.11.001. JACC Cardiovasc Interv. 2009. PMID: 20129544 No abstract available.
-
Second-generation drug-eluting stents and the continuous need for rapidly available real-world data.JACC Cardiovasc Interv. 2009 Dec;2(12):1236-9. doi: 10.1016/j.jcin.2009.10.010. JACC Cardiovasc Interv. 2009. PMID: 20129550 No abstract available.
Similar articles
-
Long-term clinical and economic analysis of the Endeavor zotarolimus-eluting stent versus the cypher sirolimus-eluting stent: 3-year results from the ENDEAVOR III trial (Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).JACC Cardiovasc Interv. 2009 Dec;2(12):1199-207. doi: 10.1016/j.jcin.2009.10.009. JACC Cardiovasc Interv. 2009. PMID: 20129546 Clinical Trial.
-
Late safety, efficacy, and cost-effectiveness of a zotarolimus-eluting stent compared with a paclitaxel-eluting stent in patients with de novo coronary lesions: 2-year follow-up from the ENDEAVOR IV trial (Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions).JACC Cardiovasc Interv. 2009 Dec;2(12):1208-18. doi: 10.1016/j.jcin.2009.10.008. JACC Cardiovasc Interv. 2009. PMID: 20129547 Clinical Trial.
-
Improved late clinical safety with zotarolimus-eluting stents compared with paclitaxel-eluting stents in patients with de novo coronary lesions: 3-year follow-up from the ENDEAVOR IV (Randomized Comparison of Zotarolimus- and Paclitaxel-Eluting Stents in Patients With Coronary Artery Disease) trial.JACC Cardiovasc Interv. 2010 Oct;3(10):1043-50. doi: 10.1016/j.jcin.2010.07.008. JACC Cardiovasc Interv. 2010. PMID: 20965463 Clinical Trial.
-
Recent progress in percutaneous coronary intervention: evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent.Coron Artery Dis. 2010 Jan;21(1):46-56. doi: 10.1097/MCA.0b013e328333f550. Coron Artery Dis. 2010. PMID: 19952925 Review.
-
Long-term risk of clinical events from stenting side branches of coronary bifurcation lesions with drug-eluting and bare-metal stents: an observational meta-analysis.Catheter Cardiovasc Interv. 2011 Feb 1;77(2):202-12. doi: 10.1002/ccd.22750. Catheter Cardiovasc Interv. 2011. PMID: 20824754 Review.
Cited by
-
Comparison of Clinical Outcomes in Patients Undergoing Coronary Intervention with Drug-Eluting Stents or Bare-Metal Stents: A Nationwide Population Study.Acta Cardiol Sin. 2017 Jan;33(1):10-19. doi: 10.6515/acs20160608a. Acta Cardiol Sin. 2017. PMID: 28115802 Free PMC article.
-
[Imaging of coronary stents using multislice computed tomography].Radiologe. 2010 Jun;50(6):507-13. doi: 10.1007/s00117-010-1990-0. Radiologe. 2010. PMID: 20521021 German.
-
Patient-level costs of major cardiovascular conditions: a review of the international literature.Clinicoecon Outcomes Res. 2016 Sep 21;8:495-506. doi: 10.2147/CEOR.S89331. eCollection 2016. Clinicoecon Outcomes Res. 2016. PMID: 27703385 Free PMC article. Review.
-
Five-Year Efficacy and Safety of TiNO-Coated Stents Versus Drug-Eluting Stents in Acute Coronary Syndrome: A Meta-Analysis.J Clin Med. 2023 Nov 6;12(21):6952. doi: 10.3390/jcm12216952. J Clin Med. 2023. PMID: 37959416 Free PMC article. Review.
-
Treatment for stable coronary artery disease: a network meta-analysis of cost-effectiveness studies.PLoS One. 2014 Jun 4;9(6):e98371. doi: 10.1371/journal.pone.0098371. eCollection 2014. PLoS One. 2014. PMID: 24896266 Free PMC article.