Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jan;3(1):90-7.
doi: 10.1016/j.jcin.2009.10.023.

Increased restenosis rate after implantation of drug-eluting stents in patients with elevated serum activity of matrix metalloproteinase-2 and -9

Affiliations
Free article

Increased restenosis rate after implantation of drug-eluting stents in patients with elevated serum activity of matrix metalloproteinase-2 and -9

Katharina M Katsaros et al. JACC Cardiovasc Interv. 2010 Jan.
Free article

Abstract

Objectives: Our aim was to test whether serum levels of matrix metalloproteinase (MMP)-2 and -9 are associated with the development of in-stent restenosis (ISR) after implantation of drug-eluting stents (DES).

Background: With the introduction of DES coronary ISR could be reduced dramatically. However, it still plays a significant role, particularly after treatment of multiple, complex lesions.

Methods: We studied 85 patients who were treated with 159 DES. Blood samples for measurement of MMP-2 and -9 antigen and activity were taken directly before and 24 h after percutaneous coronary intervention (PCI). Restenosis was evaluated at 6 to 8 months by coronary angiography.

Results: During the follow-up period, 2 patients (2.4%) died of cardiovascular causes, and 12 patients developed angiographic ISR. Patients with ISR showed significantly higher serum activity of MMP-9 at baseline (p = 0.017) and of MMP-2 (p < 0.0001) and MMP-9 (p < 0.0001) after the procedure. The PCI increased serum activity of MMP-2 (p = 0.005) and MMP-9 (p = 0.008) only in patients with ISR. The restenosis rates of patients in the highest quartile of MMP-2 after and MMP-9 before and after PCI were 40.0%, 38.9%, and 42.9% compared with 6.3%, 7.7%, and 4.0% in the lower quartiles, respectively. This was independent of clinical and procedural characteristics.

Conclusions: Elevated serum activities of MMP-2 and -9 are associated with dramatically increased restenosis rates after PCI with implantation of DES. Determination of MMP levels might be useful for identification of patients who are at high risk for ISR despite implantation of DES.