Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Jul;51(7):3433-40.
doi: 10.1167/iovs.09-4307. Epub 2010 Feb 3.

Biometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study

Affiliations

Biometry of the cornea and anterior chamber in chinese eyes: an anterior segment optical coherence tomography study

Leonard H Yuen et al. Invest Ophthalmol Vis Sci. 2010 Jul.

Abstract

PURPOSE. To investigate the normative data of corneal and anterior segment biometric parameters and their associations in Chinese adults, for use in preoperative assessment for corneal and anterior segment surgery. METHODS. This cross-sectional, population-based study included 750 subjects aged > or =50 years. The subjects underwent an ophthalmic examination including imaging with anterior segment optical coherence tomography (AS-OCT). Dimensions were subsequently measured with the Zhongshan Assessment Program (ZAP). Also measured was posterior corneal arc length (PCAL), a novel parameter defined as the arc distance between scleral spurs on the posterior border of the cornea. Correlations with age, sex, height, weight, body mass index (BMI), refractive sphere and cylinder, and intraocular pressure were also measured. RESULTS. The subjects' mean age was 63.3 +/- 7.9 years and 349 (46.5%) were men. Corneal parameters (mean +/- SD) included PCAL (12.924 +/- 0.544 mm), anterior chamber depth (ACD; 2.684 +/- 0.309 mm), central corneal thickness (562.39 +/- 31.85 microm), anterior chamber curvature (7.35 +/- 0.37 mm), and posterior corneal curvature (6.65 +/- 0.34 mm). A moderate correlation was observed between PCAL and ACD (R = 0.55, P < 0.001) and a poor correlation between PCAL and age, height, weight, and BMI. Multivariate analysis showed a significant association between PCAL and ACD, ACC, PCC, and cylinder (P < 0.05). CONCLUSIONS. In this Chinese population, PCAL was found to correlate moderately with ACD. The data may be useful for corneal and anterior segment procedures such as Descemet's stripping automated endothelial keratoplasty (DSAEK).

PubMed Disclaimer

Publication types

LinkOut - more resources