Sagittal flexion angle of the femoral component in unicompartmental knee arthroplasty: is it same for both medial and lateral UKAs?
- PMID: 20130835
- DOI: 10.1007/s00167-010-1063-y
Sagittal flexion angle of the femoral component in unicompartmental knee arthroplasty: is it same for both medial and lateral UKAs?
Abstract
The flexion of the femoral component in the sagittal plane in unicompartmental knee arthroplasty (UKA) was analyzed radiographically in this study. Thirty medial and 30 lateral UKAs were included. The sagittal flexion angles were measured both relative to the posterior femoral cortex and midline sagittal distal femoral axis. Both of the measurement methods revealed that the femoral components were inserted in a significantly more flexed fashion in the medial UKA group. Neither preoperative nor postoperative tibial slope did have any significant effect on the sagittal flexion angle. To the best of our knowledge, this is the first study demonstrating an angular difference in the sagittal flexion of the femoral components between medial and lateral UKAs.
Similar articles
-
What effect does preoperative flexion contracture have on the component angles in unicompartmental knee arthroplasty?Eur J Orthop Surg Traumatol. 2024 May;34(4):2185-2191. doi: 10.1007/s00590-024-03929-3. Epub 2024 Apr 4. Eur J Orthop Surg Traumatol. 2024. PMID: 38573382
-
Biomechanical effect with respect to the sagittal positioning of the femoral component in unicompartmental knee arthroplasty.Biomed Mater Eng. 2019;30(2):171-182. doi: 10.3233/BME-191042. Biomed Mater Eng. 2019. PMID: 30741665
-
Rotational alignment errors can occur in unicompartmental knee arthroplasty if anatomical landmarks are misused: A preoperative CT scan analysis.Knee. 2020 Jan;27(1):242-248. doi: 10.1016/j.knee.2019.10.003. Epub 2019 Dec 24. Knee. 2020. PMID: 31875837
-
In vivo kinematic comparison before and after mobile-bearing unicompartmental knee arthroplasty during high-flexion activities.Knee. 2020 Jun;27(3):878-883. doi: 10.1016/j.knee.2020.03.002. Epub 2020 Apr 13. Knee. 2020. PMID: 32299758
-
Accuracy of implantation during computer-assisted minimally invasive Oxford unicompartmental knee arthroplasty: a comparison with a conventional instrumented technique.Knee. 2010 Dec;17(6):387-91. doi: 10.1016/j.knee.2009.11.003. Epub 2009 Nov 28. Knee. 2010. PMID: 19945880
Cited by
-
Anteroposterior and rotational stability in fixed and mobile bearing unicondylar knee arthroplasty: a cadaveric study using the robotic force sensor system.Knee Surg Sports Traumatol Arthrosc. 2013 Nov;21(11):2427-32. doi: 10.1007/s00167-012-2157-5. Epub 2012 Aug 7. Knee Surg Sports Traumatol Arthrosc. 2013. PMID: 22868351
-
Inaccurate rotational component position in image-free navigated unicompartmental knee arthroplasty.Asia Pac J Sports Med Arthrosc Rehabil Technol. 2016 Jan 26;3:19-24. doi: 10.1016/j.asmart.2015.12.002. eCollection 2016 Jan. Asia Pac J Sports Med Arthrosc Rehabil Technol. 2016. PMID: 29264256 Free PMC article.
-
Shallow knee flexion angle during femoral tunnel creation using modified transtibial technique can reduce femoral graft bending angle in ACL reconstruction.Knee Surg Sports Traumatol Arthrosc. 2019 Feb;27(2):618-625. doi: 10.1007/s00167-018-5191-0. Epub 2018 Oct 9. Knee Surg Sports Traumatol Arthrosc. 2019. PMID: 30302534
-
Sagittal placement of the femoral component in total knee arthroplasty predicts knee flexion contracture at one-year follow-up.Int Orthop. 2012 Sep;36(9):1835-9. doi: 10.1007/s00264-012-1580-z. Epub 2012 May 27. Int Orthop. 2012. PMID: 22638608 Free PMC article.
-
The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement.Cureus. 2023 Aug 4;15(8):e42956. doi: 10.7759/cureus.42956. eCollection 2023 Aug. Cureus. 2023. PMID: 37667718 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical