Improved B(0) field map estimation for high field EPI
- PMID: 20133097
- DOI: 10.1016/j.mri.2009.12.020
Improved B(0) field map estimation for high field EPI
Abstract
Echo planar imaging (EPI) is an ultrafast magnetic resonance imaging (MRI) technique that allows one to acquire a 2D image in about 100 ms. Unfortunately, the standard EPI images suffer from substantial geometric distortions, mainly originating from susceptibility differences in adjacent tissues. To reduce EPI distortions, correction methods based on a field map, which is a map of the off-resonance frequencies, have been developed. In this work, a nonlinear least squares estimator is used to optimize the estimation of the field map of the B(0) field. The model of the EPI and reference data includes parameters for the phase evolution, the complex magnitude, the relaxation of the MRI signal and the EPI-specific phase difference between odd and even echoes, and from these parameters, additional corrections might be computed. The reference data required to estimate the field map can be acquired with a modified EPI-sequence. The proposed method is tested on simulated as well as experimental data and proves to be significantly more robust against noise, compared to the previously suggested method.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation.IEEE Trans Med Imaging. 2003 Feb;22(2):200-5. doi: 10.1109/TMI.2002.808362. IEEE Trans Med Imaging. 2003. PMID: 12715996
-
EPI image reconstruction with correction of distortion and signal losses.J Magn Reson Imaging. 2006 Sep;24(3):683-9. doi: 10.1002/jmri.20672. J Magn Reson Imaging. 2006. PMID: 16892198
-
Double-spin-echo diffusion weighting with a modified eddy current adjustment.Magn Reson Imaging. 2010 Apr;28(3):434-40. doi: 10.1016/j.mri.2009.12.004. Epub 2010 Jan 13. Magn Reson Imaging. 2010. PMID: 20071120
-
Ultrafast imaging: principles, pitfalls, solutions, and applications.J Magn Reson Imaging. 2010 Aug;32(2):252-66. doi: 10.1002/jmri.22239. J Magn Reson Imaging. 2010. PMID: 20677249 Review.
-
[Functional MRI using interleaved EPI].Nihon Rinsho. 1997 Jul;55(7):1666-9. Nihon Rinsho. 1997. PMID: 9233005 Review. Japanese.
Cited by
-
High-resolution steady-state cerebral blood volume maps in patients with central nervous system neoplasms using ferumoxytol, a superparamagnetic iron oxide nanoparticle.J Cereb Blood Flow Metab. 2013 May;33(5):780-6. doi: 10.1038/jcbfm.2013.36. Epub 2013 Mar 13. J Cereb Blood Flow Metab. 2013. PMID: 23486297 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources