Colour Doppler ultrasonography evaluation of vascularization in the wrist and finger joints in rheumatoid arthritis patients and healthy subjects
- PMID: 20138722
- DOI: 10.1016/j.ejrad.2010.01.005
Colour Doppler ultrasonography evaluation of vascularization in the wrist and finger joints in rheumatoid arthritis patients and healthy subjects
Abstract
Objectives: To evaluate the presence of blood flow by colour Doppler ultrasonography (CDUS) in the wrist and finger joints of rheumatoid arthritis (RA) patients and healthy subjects and to define a cut-off value of CDUS resistive index (RI).
Methods: Forty-three patients with RA and 43 healthy controls were examined by CDUS. The wrists, second and third metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints were evaluated in each patient and healthy subject. Spectral Doppler analysis was performed in order to characterize the type of flow and a mean RI was measured to define a cut-off level. The area under receiver operating characteristic curve was used to evaluate the screening method's performance.
Results: Flow was detected in 219 of the 430 total joints (50.9%) of RA patients (111 in the wrists, 49 in the MCP and 30 in the PIP joints). Healthy subjects had a quantifiable flow in 45 of the 430 joints (10.5%) and, in particular, 39 (86.4%) in the wrist, 5 (11.14%) in the MCP and 1 (2.2%) in the PIP joints. The intra- and inter-reader agreements for the detection of Doppler signal were very good (kappa 0.82 and 0.89, respectively). Mean RI values were 0.72±0.06 in RA patients and 0.86±0.06 in healthy subjects (p<0.01). At cut-off point of RI<0.79 the sensitivity was 89.6% and the specificity was 78.8% (positive likelihood ratio 4.22).
Conclusion: DUS is a useful tool for the detection of abnormal blood flow in inflammatory joints of RA patients.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Comment in
-
Complex appearance of vascularization in the wrist and finger joints in rheumatoid arthritis patients.Eur J Radiol. 2012 Aug;81(8):1967. doi: 10.1016/j.ejrad.2010.08.032. Epub 2010 Sep 18. Eur J Radiol. 2012. PMID: 20851543 No abstract available.
Similar articles
-
The value of contrast-enhanced color Doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis.Arthritis Rheum. 2002 Mar;46(3):647-53. doi: 10.1002/art.10136. Arthritis Rheum. 2002. PMID: 11920400
-
Doppler ultrasound findings in healthy wrists and finger joints.Ann Rheum Dis. 2004 Jun;63(6):644-8. doi: 10.1136/ard.2003.009548. Ann Rheum Dis. 2004. PMID: 15140770 Free PMC article.
-
Diagnostic sensitivity and specificity of Doppler ultrasound in rheumatoid arthritis.J Rheumatol. 2008 Jan;35(1):49-53. Epub 2007 Dec 15. J Rheumatol. 2008. PMID: 18172922 Clinical Trial.
-
Color fraction as a useful method of imaging synovium vascularization in patients with high activity of rheumatoid arthritis.Reumatologia. 2020;58(1):42-47. doi: 10.5114/reum.2020.93513. Epub 2020 Feb 28. Reumatologia. 2020. PMID: 32322123 Free PMC article. Review.
-
Colour Doppler energy (power) mode ultrasound.Clin Radiol. 1996 Jun;51(6):387-90. doi: 10.1016/s0009-9260(96)80155-3. Clin Radiol. 1996. PMID: 8654001 Review. No abstract available.
Cited by
-
In vivo quantification of collagen-induced arthritis mouse model by three-dimensional volumetric ultrasound and color Doppler.PLoS One. 2025 Apr 7;20(4):e0321124. doi: 10.1371/journal.pone.0321124. eCollection 2025. PLoS One. 2025. PMID: 40193352 Free PMC article.
-
Ultrasonography in inflammatory rheumatic disease: an overview.Nat Rev Rheumatol. 2011 Jul 12;7(8):479-88. doi: 10.1038/nrrheum.2011.95. Nat Rev Rheumatol. 2011. PMID: 21750529 Review.
-
The value of ultrasound and magnetic resonance imaging scoring systems in explaining handgrip strength and functional impairment in rheumatoid arthritis patients: a pilot study.Radiol Med. 2022 Jun;127(6):652-663. doi: 10.1007/s11547-022-01499-0. Epub 2022 May 14. Radiol Med. 2022. PMID: 35567732 Free PMC article.
-
Handgrip Strength Features in Rheumatoid Arthritis Patients Assessed Using an Innovative Cylindrical-Shaped Device: Relationships With Demographic, Anthropometric and Clinical Variables.J Med Syst. 2021 Oct 9;45(11):100. doi: 10.1007/s10916-021-01778-9. J Med Syst. 2021. PMID: 34628537 Free PMC article.
-
Quantitative analysis of vascularization in the finger joints in patients with rheumatoid arthritis using three-dimensional volumetric ultrasonography with power Doppler.Clin Rheumatol. 2012 Feb;31(2):299-307. doi: 10.1007/s10067-011-1811-5. Epub 2011 Jul 28. Clin Rheumatol. 2012. PMID: 21796350
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous