High-resolution cartilage imaging of the knee at 3T: basic evaluation of modern isotropic 3D MR-sequences
- PMID: 20138723
- DOI: 10.1016/j.ejrad.2010.01.008
High-resolution cartilage imaging of the knee at 3T: basic evaluation of modern isotropic 3D MR-sequences
Abstract
Purpose: To evaluate qualitative and quantitative image quality parameters of isotropic three-dimensional (3D) cartilage-imaging magnetic resonance (MR)-sequences at 3T.
Materials and methods: The knees of 10 healthy volunteers (mean age, 24.4±5.6 years) were scanned at a 3T MR scanner with water-excited 3D Fast-Low Angle Shot (FLASH), True Fast Imaging with Steady-state Precession (TrueFISP), Sampling Perfection with Application-optimized Contrast using different flip-angle Evolutions (SPACE) as well as conventional and two individually weighted Double-Echo Steady-State (DESS) sequences. The MR images were evaluated qualitatively and quantitatively (signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), SNR efficiency, CNR efficiency). Quantitative parameters were compared by means of a Tukey-test and sequences were ranked according to SNR/CNR, SNR/CNR efficiency and qualitative image grading.
Results: The highest SNR was measured for SPACE (34.0±5.6), the highest CNR/CNR efficiency (cartilage/fluid) for the individually weighted DESS (46.9±18.0/2.18±0.84). SPACE, individually weighted and conventional DESS were ranked best with respect to SNR/CNR and SNR/CNR efficiency. The DESS sequences also performed best in the qualitative evaluation. TrueFISP performed worse, FLASH worst. The individually weighted DESS sequences were generally better than the conventional DESS with the significant increase of cartilage-fluid contrast (46.9±18.0/31.9±11.4 versus 22.0±7.3) as main advantage.
Conclusion: Individually weighted DESS is the most promising candidate; all tested sequences performed better than FLASH.
Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
[Comparison between pig lumbar zypapophyseal joint cartilage acquired from multiple magnetic resonance image sequences and gross specimens].Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2010 Oct;35(10):1064-72. doi: 10.3969/j.issn.1672-7347.2010.10.006. Zhong Nan Da Xue Xue Bao Yi Xue Ban. 2010. PMID: 21051831 Chinese.
-
MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence.Invest Radiol. 2009 Sep;44(9):585-97. doi: 10.1097/RLI.0b013e3181b4c1a1. Invest Radiol. 2009. PMID: 19668001
-
Three-dimensional magnetic resonance observation of cartilage repair tissue (MOCART) score assessed with an isotropic three-dimensional true fast imaging with steady-state precession sequence at 3.0 Tesla.Invest Radiol. 2009 Sep;44(9):603-12. doi: 10.1097/RLI.0b013e3181b5333c. Invest Radiol. 2009. PMID: 19692843 Clinical Trial.
-
The osteoarthritis initiative: report on the design rationale for the magnetic resonance imaging protocol for the knee.Osteoarthritis Cartilage. 2008 Dec;16(12):1433-41. doi: 10.1016/j.joca.2008.06.016. Epub 2008 Sep 10. Osteoarthritis Cartilage. 2008. PMID: 18786841 Free PMC article. Review.
-
Steady-state MR imaging sequences: physics, classification, and clinical applications.Radiographics. 2008 Jul-Aug;28(4):1147-60. doi: 10.1148/rg.284075031. Radiographics. 2008. PMID: 18635634 Review.
Cited by
-
Correction of B0 and linear eddy currents: Impact on morphological and quantitative ultrashort echo time double echo steady state (UTE-DESS) imaging.NMR Biomed. 2023 Mar 25:e4939. doi: 10.1002/nbm.4939. Online ahead of print. NMR Biomed. 2023. PMID: 36965076 Free PMC article.
-
MR-Imaging in Osteoarthritis: Current Standard of Practice and Future Outlook.Diagnostics (Basel). 2023 Aug 3;13(15):2586. doi: 10.3390/diagnostics13152586. Diagnostics (Basel). 2023. PMID: 37568949 Free PMC article. Review.
-
Mechanisms of osteoarthritis in the knee: MR imaging appearance.J Magn Reson Imaging. 2014 Jun;39(6):1346-56. doi: 10.1002/jmri.24562. Epub 2014 Feb 19. J Magn Reson Imaging. 2014. PMID: 24677706 Free PMC article. Review.
-
3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times.Eur Radiol. 2017 Nov;27(11):4563-4570. doi: 10.1007/s00330-017-4816-x. Epub 2017 Apr 21. Eur Radiol. 2017. PMID: 28432504
-
Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.Skeletal Radiol. 2017 Nov;46(11):1487-1498. doi: 10.1007/s00256-017-2714-6. Epub 2017 Jul 17. Skeletal Radiol. 2017. PMID: 28717928
MeSH terms
LinkOut - more resources
Full Text Sources
Medical