Compton scatter imaging: A tool for historical exploration
- PMID: 20138773
- DOI: 10.1016/j.apradiso.2010.01.035
Compton scatter imaging: A tool for historical exploration
Abstract
This review discusses the principles and technological realisation of a technique, termed Compton scatter imaging (CSI), which is based on spatially resolved detection of Compton scattered X-rays. The applicational focus of this review is to objects of historical interest. Following a historical survey of CSI, a description is given of the major characteristics of Compton X-ray scatter. In particular back-scattered X-rays allow massive objects to be imaged, which would otherwise be too absorbing for the conventional transmission X-ray technique. The ComScan (an acronym for Compton scatter scanner) is a commercially available backscatter imaging system, which is discussed here in some detail. ComScan images from some artefacts of historical interest, namely a fresco, an Egyptian mummy and a mediaeval clasp are presented and their use in historical analysis is indicated. The utility of scientific and technical advance for not only exploring history, but also restoring it, is briefly discussed.
Copyright 2010 Elsevier Ltd. All rights reserved.
Similar articles
-
Dual-energy Compton scatter tomography.Phys Med Biol. 1986 May;31(5):477-89. doi: 10.1088/0031-9155/31/5/001. Phys Med Biol. 1986. PMID: 3737685
-
Compton scatter imaging of transverse sections: corrections for multiple scatter and attenuation.Phys Med Biol. 1977 Mar;22(2):229-44. doi: 10.1088/0031-9155/22/2/004. Phys Med Biol. 1977. PMID: 854523
-
A K edge filter technique for optimization of the coherent-to-Compton scatter ratio method.Med Phys. 1995 Dec;22(12):2007-14. doi: 10.1118/1.597497. Med Phys. 1995. PMID: 8746705
-
Short Review: The Use of Conventional X-rays in Mummy Studies.Anat Rec (Hoboken). 2015 Jun;298(6):1085-7. doi: 10.1002/ar.23147. Anat Rec (Hoboken). 2015. PMID: 25998642 Review.
-
Review of Development and Recent Advances in Biomedical X-ray Fluorescence Imaging.Int J Mol Sci. 2023 Jul 1;24(13):10990. doi: 10.3390/ijms241310990. Int J Mol Sci. 2023. PMID: 37446168 Free PMC article. Review.
Cited by
-
Dose-efficient scanning Compton X-ray microscopy.Light Sci Appl. 2023 May 30;12(1):130. doi: 10.1038/s41377-023-01176-5. Light Sci Appl. 2023. PMID: 37248250 Free PMC article.
-
Novel Zeff imaging method for deep internal areas using back-scattered X-rays.Sci Rep. 2019 Dec 11;9(1):18831. doi: 10.1038/s41598-019-54907-3. Sci Rep. 2019. PMID: 31827112 Free PMC article.
-
Compton scattering imaging of a working battery using synchrotron high-energy X-rays.J Synchrotron Radiat. 2015 Jan;22(1):161-4. doi: 10.1107/S1600577514024321. Epub 2015 Jan 1. J Synchrotron Radiat. 2015. PMID: 25537603 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical