Glucose meters: a review of technical challenges to obtaining accurate results
- PMID: 20144348
- PMCID: PMC2769957
- DOI: 10.1177/193229680900300446
Glucose meters: a review of technical challenges to obtaining accurate results
Abstract
Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results.
Copyright 2009 Diabetes Technology Society.
Similar articles
-
Capillary and Venous Blood Glucose Accuracy in Blood Glucose Meters Versus Reference Standards: The Impact of Study Design on Accuracy Evaluations.J Diabetes Sci Technol. 2019 May;13(3):546-552. doi: 10.1177/1932296818790228. Epub 2018 Aug 7. J Diabetes Sci Technol. 2019. PMID: 30084263 Free PMC article.
-
Comparative Accuracy Evaluation of a Blood Glucose Meter With Novel Hematocrit Correction Technology, With Three Currently Used Commercially Available Blood Glucose Monitoring Systems.J Diabetes Sci Technol. 2019 May;13(3):568-574. doi: 10.1177/1932296818821389. Epub 2019 Jan 9. J Diabetes Sci Technol. 2019. PMID: 30623673 Free PMC article.
-
Accuracy of home blood glucose meters during hypoglycemia.Diabetes Care. 1996 Dec;19(12):1412-5. doi: 10.2337/diacare.19.12.1412. Diabetes Care. 1996. PMID: 8941473
-
A Perspective on the Accuracy of Blood Glucose Meters During Pregnancy.Diabetes Care. 2018 Oct;41(10):2053-2058. doi: 10.2337/dc18-0833. Diabetes Care. 2018. PMID: 30237233 Review.
-
Assessing glucose meter accuracy.Curr Med Res Opin. 2006 Nov;22(11):2167-74. doi: 10.1185/030079906X148274. Curr Med Res Opin. 2006. PMID: 17076977 Review.
Cited by
-
Biosensors for Public Health and Environmental Monitoring: The Case for Sustainable Biosensing.ACS Sustain Chem Eng. 2024 Jul 1;12(28):10296-10312. doi: 10.1021/acssuschemeng.3c06112. eCollection 2024 Jul 15. ACS Sustain Chem Eng. 2024. PMID: 39027730 Free PMC article. Review.
-
Basal-Bolus Insulin Regimen for Hospitalised Patients with COVID-19 and Diabetes Mellitus: A Practical Approach.Diabetes Ther. 2020 Sep;11(9):2177-2194. doi: 10.1007/s13300-020-00873-3. Epub 2020 Jul 18. Diabetes Ther. 2020. PMID: 32683660 Free PMC article.
-
Noninvasive Electromagnetic Wave Sensing of Glucose.Sensors (Basel). 2019 Mar 7;19(5):1151. doi: 10.3390/s19051151. Sensors (Basel). 2019. PMID: 30866459 Free PMC article. Review.
-
Chelonid Alphaherpesvirus 5 DNA in Fibropapillomatosis-Affected Chelonia mydas.Ecohealth. 2019 Jun;16(2):248-259. doi: 10.1007/s10393-019-01412-8. Epub 2019 May 23. Ecohealth. 2019. PMID: 31124021
-
Design and Prestudy Assessment of a Dashboard for Presenting Self-Collected Health Data of Patients With Diabetes to Clinicians: Iterative Approach and Qualitative Case Study.JMIR Diabetes. 2019 Jul 9;4(3):e14002. doi: 10.2196/14002. JMIR Diabetes. 2019. PMID: 31290396 Free PMC article.
References
-
- Mendosa D. Meter memories. How Tom, Dick, and Charlie did it. Diabetes Wellness Letter. 2000;1(6)
-
- Bernstein RK. London: Little Brown; 1997. Dr. Bernstein's diabetes solution. A complete guide to achieving normal blood sugars.
-
- Dufaitre-Patouraux L, Vague P, Lassmann-Vague V. History, accuracy and precision of SMBG devices. Diabetes Metab. 2003;29 (2 Pt 2):S7–14. - PubMed
-
- American Diabetes Association. Standards of medical care in diabetes–2008. Diabetes Care. 2008;31(Suppl 1):S12–S54. - PubMed
-
- Van den Berghe G, Wilmer A, Hermans G, Meersseman W, Wouters PJ, Milants I, Van Wijngaerden E, Bobbaers H, Bouillon R. Intensive insulin therapy in the medical ICU. N Engl J Med. 2006;354(5):449–461. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical