Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump
- PMID: 20144395
- PMCID: PMC2787041
- DOI: 10.1177/193229680900300621
Treatment satisfaction and quality of life for an integrated continuous glucose monitoring/insulin pump system compared to self-monitoring plus an insulin pump
Abstract
Background: Little is known about how the most advanced technology affects treatment satisfaction and health-related quality of life (HRQOL) in adults with diabetes. This study was designed to assess treatment satisfaction and HRQOL among users of an integrated real-time (RT) continuous glucose monitoring (CGM)/continuous subcutaneous insulin infusion (CSII) system compared with those using self-monitoring of blood glucose (SMBG) with CSII.
Methods: Participants were 311 adult respondents to an Internet survey, 162 using RT-CGM/CSII, 149 using SMBG + CSII (median age 43 years; type 1 diabetes 94%; diabetes duration >15 years 61%; median insulin use 15 years). Respondents completed instruments assessing glucose monitoring system and insulin delivery system convenience, interference, burden, glucose control efficacy, cost satisfaction, overall satisfaction, and treatment preference, as well as quality of life (diabetes-related worries, social burden, and psychological well-being). Real-time CGM/CSII users also assessed specific elements of the RT-CGM/CSII system. Group differences were assessed using analysis of covariance controlling for respondent characteristics.
Results: The RT-CGM/CSII group gave significantly better ratings than the SMBG + CSII group for their glucose monitoring system's glucose control efficacy, overall satisfaction, desire to switch, and willingness to recommend, and significantly worse ratings for interference with daily activities. The RT-CGM/CSII group gave significantly better ratings than the SMBG + CSII group for their insulin delivery system's convenience and glucose control efficacy, overall satisfaction, desire to switch, and willingness to recommend. Real-time CGM/CSII users gave positive ratings of all system features.
Conclusions: Users of the integrated RT-CGM/CSII system reported more benefits of treatment, higher treatment satisfaction and quality of life, and greater preference for this system than SMBG + CSII users.
Similar articles
-
Cost-effectiveness of sensor-augmented pump therapy in two different patient populations with type 1 diabetes in Italy.Nutr Metab Cardiovasc Dis. 2018 Jul;28(7):707-715. doi: 10.1016/j.numecd.2018.03.011. Epub 2018 Apr 5. Nutr Metab Cardiovasc Dis. 2018. PMID: 29753586
-
Patient-reported outcomes for an integrated real-time continuous glucose monitoring/insulin pump system.Diabetes Technol Ther. 2009 Jan;11(1):57-62. doi: 10.1089/dia.2008.0002. Diabetes Technol Ther. 2009. PMID: 19132857 Clinical Trial.
-
Cost-effectiveness of Initiating an Insulin Pump in T1D Adults Using Continuous Glucose Monitoring Compared with Multiple Daily Insulin Injections: The DIAMOND Randomized Trial.Med Decis Making. 2018 Nov;38(8):942-953. doi: 10.1177/0272989X18803109. Med Decis Making. 2018. PMID: 30403576 Free PMC article. Clinical Trial.
-
Optimizing type 1 diabetes after multiple daily injections and capillary blood monitoring: Pump or sensor first? A meta-analysis using pooled differences in outcome measures.Diabetes Obes Metab. 2021 Nov;23(11):2521-2528. doi: 10.1111/dom.14498. Epub 2021 Aug 12. Diabetes Obes Metab. 2021. PMID: 34286892
-
Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.Diabetes Care. 2018 Aug;41(8):1579-1589. doi: 10.2337/dci18-0002. Epub 2018 Jun 23. Diabetes Care. 2018. PMID: 29936424 Free PMC article. Review.
Cited by
-
Increasing Continuous Glucose Monitoring Use for Non-Hispanic Black and Hispanic People With Type 1 Diabetes: Results From the T1D Exchange Quality Improvement Collaborative Equity Study.Clin Diabetes. 2024 Winter;42(1):40-48. doi: 10.2337/cd23-0050. Epub 2023 Oct 13. Clin Diabetes. 2024. PMID: 38230339 Free PMC article.
-
Diabetes Educators: Perceived Experiences, Supports and Barriers to Use of Common Diabetes-Related Technologies.J Diabetes Sci Technol. 2016 Aug 22;10(5):1115-21. doi: 10.1177/1932296816660326. Print 2016 Sep. J Diabetes Sci Technol. 2016. PMID: 27417141 Free PMC article.
-
Influences on Technology Use and Efficacy in Type 1 Diabetes.J Diabetes Sci Technol. 2016 May 3;10(3):647-55. doi: 10.1177/1932296816639315. Print 2016 May. J Diabetes Sci Technol. 2016. PMID: 27022096 Free PMC article. Review.
-
Disparities in Continuous Glucose Monitoring Among Patients Receiving Care in Federally Qualified Health Centers.JAMA Netw Open. 2024 Nov 4;7(11):e2445316. doi: 10.1001/jamanetworkopen.2024.45316. JAMA Netw Open. 2024. PMID: 39576644 Free PMC article.
-
Diabetes Device Use in Adults With Type 1 Diabetes: Barriers to Uptake and Potential Intervention Targets.Diabetes Care. 2017 Feb;40(2):181-187. doi: 10.2337/dc16-1536. Epub 2016 Nov 29. Diabetes Care. 2017. PMID: 27899489 Free PMC article.
References
-
- Hirsch IB, Abelseth J, Bode BW, Fischer JS, Kaufman FR, Mastrototaro J, Parkin CG, Wolpert HA, Buckingham BA. Sensor-augmented insulin pump therapy: results of the first randomized treat-to-target study. Diabetes Technol Ther. 2008;10(5):377–383. - PubMed
-
- Reach G. Continuous glucose monitoring and diabetes health outcomes: a critical appraisal. Diabetes Technol Ther. 2008;10(2):69–80. - PubMed
-
- Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S, Jovanovic L. Improvement in glycemic excursions with a trans-cutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care. 2006;29(1):44–50. - PubMed
-
- Bode B, Gross K, Rikalo N, Schwartz S, Wahl T, Page C, Gross T, Mastrototaro J. Alarms based on real-time sensor glucose values alert patients to hypo- and hyperglycemia: the guardian continuous monitoring system. Diabetes Technol Ther. 2004;6(2):105–113. - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical