Progress in development of an artificial pancreas
- PMID: 20144412
- PMCID: PMC2769889
- DOI: 10.1177/193229680900300502
Progress in development of an artificial pancreas
Abstract
This issue of Journal of Diabetes Science and Technology contains a collection of 12 original articles describing the latest advances in the development of algorithms for controlling insulin delivery in an artificial pancreas. Algorithms presented in this issue are affected by numerous quantifiable factors, including insulin pharmaco-kinetics, timing of meal carbohydrate appearance, meal size, amount of exercise, presence of stress, day-to-day variations in insulin sensitivity, insulin time-activity profiles, accuracy of glucose monitor calibration, metabolic profiles of both adults and neonates, and risks of hypoglycemia/hyperglycemia. These articles present theoretical advances in insulin delivery algorithms from modeled in silico patients, as well as clinical data from actual patients who have used closed loop systems. The novel approaches described in these articles are expected to bring us much closer to realization of a commercially available closed loop system for controlling glucose levels in patients with diabetes.
2009 Diabetes Technology Society.
Similar articles
-
A closed-loop artificial pancreas using model predictive control and a sliding meal size estimator.J Diabetes Sci Technol. 2009 Sep 1;3(5):1082-90. doi: 10.1177/193229680900300511. J Diabetes Sci Technol. 2009. PMID: 20144421 Free PMC article.
-
Identification of intraday metabolic profiles during closed-loop glucose control in individuals with type 1 diabetes.J Diabetes Sci Technol. 2009 Sep 1;3(5):1047-57. doi: 10.1177/193229680900300508. J Diabetes Sci Technol. 2009. PMID: 20144418 Free PMC article.
-
Continuous Glucose Monitoring, Future Products, and Update on Worldwide Artificial Pancreas Projects.Diabetes Technol Ther. 2016 Feb;18 Suppl 2(Suppl 2):S253-63. doi: 10.1089/dia.2015.0345. Diabetes Technol Ther. 2016. PMID: 26784131 Free PMC article. Review.
-
Glucose clamp algorithms and insulin time-action profiles.J Diabetes Sci Technol. 2009 Sep 1;3(5):1005-13. doi: 10.1177/193229680900300503. J Diabetes Sci Technol. 2009. PMID: 20144413 Free PMC article. Review.
-
Closing the Loop.Diabetes Technol Ther. 2016 Feb;18 Suppl 1:S29-42. doi: 10.1089/dia.2016.2504. Diabetes Technol Ther. 2016. PMID: 26836427 Review. No abstract available.
Cited by
-
The need for a glycemia modeling comparison workshop to facilitate development of an artificial pancreas.J Diabetes Sci Technol. 2010 Jan 1;4(1):1-3. doi: 10.1177/193229681000400101. J Diabetes Sci Technol. 2010. PMID: 20167161 Free PMC article. No abstract available.
-
Intensive insulin therapy in critically ill hospitalized patients: making it safe and effective.J Diabetes Sci Technol. 2011 May 1;5(3):755-67. doi: 10.1177/193229681100500330. J Diabetes Sci Technol. 2011. PMID: 21722591 Free PMC article. Review.
-
Premeal injection of rapid-acting insulin reduces postprandial glycemic excursions in type 1 diabetes.Diabetes Care. 2010 Oct;33(10):2152-5. doi: 10.2337/dc10-0692. Epub 2010 Aug 6. Diabetes Care. 2010. PMID: 20693354 Free PMC article. Clinical Trial.
-
Factors influencing the effectiveness of glucagon for preventing hypoglycemia.J Diabetes Sci Technol. 2010 Nov 1;4(6):1305-10. doi: 10.1177/193229681000400603. J Diabetes Sci Technol. 2010. PMID: 21129324 Free PMC article.
-
Wearable and implantable pancreas substitutes.J Artif Organs. 2013 Mar;16(1):9-22. doi: 10.1007/s10047-012-0660-6. Epub 2012 Sep 20. J Artif Organs. 2013. PMID: 22990986 Review.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical