Case Reports
. 2010 Mar 1;75(4):644-7.
doi: 10.1002/ccd.22358.

CT angiography for assessment of intracranial basilar apex aneurysm neck diameter reduction poststenting for treatment planning

Affiliations
Case Reports

CT angiography for assessment of intracranial basilar apex aneurysm neck diameter reduction poststenting for treatment planning

Joseph G Adel et al. Catheter Cardiovasc Interv. .

Abstract

Background and purpose: Once a contraindication for a neuro-interventional therapeutic approach, some wide-necked aneurysms can now be treated with stent assistance. Radiologically assessing the impact of a stent on the neck of a wide-neck bifurcation, aneurysm remains a challenge however.

Methods: A 76-year-old female with a large irregular basilar apex aneurysm was referred for endovascular treatment. Angiographic imaging revealed a basilar apex aneurysm with a 6-mm neck and a 14-mm dome. The decision was made to perform staged stent-assisted coiling of the aneurysm. In the interim time, although the stent was allowed to heal in place, a CTA was done to assess the positioning of the stent and the degree of neck narrowing.

Results: The CTA showed that the neck had been narrowed from 6 to 2 mm hence making endovascular coiling feasible.

Conclusion: Our case illustrates the use of CTA poststent deployment to visualize the change in aneurysm neck caliber precoil embolization.

PubMed Disclaimer

Publication types