Dye loading with patch pipettes
- PMID: 20147143
- DOI: 10.1101/pdb.prot5201
Dye loading with patch pipettes
Abstract
This protocol describes the loading of individual cells with fluorescent probes via patch pipettes. The patch-clamp methodology has been successfully used for single-cell dye labeling in cultured neurons, brain slices, and in vivo preparations. A broad range of dyes can be used with this loading technique. Markers for morphological reconstruction (e.g., Lucifer yellow); ion-sensitive indicator dyes for monitoring second-messenger cascades (e.g., fura-2); and dye-labeled proteins for fluorescence resonance energy transfer (FRET), fluorescence correlation spectroscopy (FCS), and fluorescence recovery after photobleaching (FRAP) studies are all suitable for patch-clamp loading. The most widespread application of this technique has been for Ca(2+) imaging. Whole-cell patch-clamp recordings represent a versatile loading technique that allows combined electrophysiological and optical measurements at a quantitative level.
Similar articles
-
Fluorescent pipettes for optically targeted patch-clamp recordings.Neural Netw. 2010 Aug;23(6):669-72. doi: 10.1016/j.neunet.2010.02.004. Epub 2010 Feb 24. Neural Netw. 2010. PMID: 20223634
-
Patch-clamp fluorometry recording of conformational rearrangements of ion channels.Sci STKE. 2003 Apr 1;2003(176):PL7. doi: 10.1126/stke.2003.176.pl7. Sci STKE. 2003. PMID: 12671191
-
Quantum dot-based multiphoton fluorescent pipettes for targeted neuronal electrophysiology.Nat Methods. 2014 Dec;11(12):1237-1241. doi: 10.1038/nmeth.3146. Epub 2014 Oct 19. Nat Methods. 2014. PMID: 25326662 Free PMC article.
-
FRET and FCS--friends or foes?Chemphyschem. 2011 Feb 25;12(3):532-41. doi: 10.1002/cphc.201000776. Epub 2011 Feb 9. Chemphyschem. 2011. PMID: 21308943 Review.
-
The power and prospects of fluorescence microscopies and spectroscopies.Annu Rev Biophys Biomol Struct. 2003;32:161-82. doi: 10.1146/annurev.biophys.32.110601.142525. Epub 2003 Feb 11. Annu Rev Biophys Biomol Struct. 2003. PMID: 12598370 Review.
Cited by
-
Robotic platform for microinjection into single cells in brain tissue.EMBO Rep. 2019 Oct 4;20(10):e47880. doi: 10.15252/embr.201947880. Epub 2019 Aug 30. EMBO Rep. 2019. PMID: 31469223 Free PMC article.
-
Accurate signal-source localization in brain slices by means of high-density microelectrode arrays.Sci Rep. 2019 Jan 28;9(1):788. doi: 10.1038/s41598-018-36895-y. Sci Rep. 2019. PMID: 30692552 Free PMC article.
-
Imaging Sodium Flux during Action Potentials in Neurons with Fluorescent Nanosensors and Transparent Microelectrodes.ACS Sens. 2018 Dec 28;3(12):2499-2505. doi: 10.1021/acssensors.8b00903. Epub 2018 Oct 25. ACS Sens. 2018. PMID: 30358986 Free PMC article.
-
Loading a Calcium Dye into Frog Nerve Endings Through the Nerve Stump: Calcium Transient Registration in the Frog Neuromuscular Junction.J Vis Exp. 2017 Jul 8;(125):55122. doi: 10.3791/55122. J Vis Exp. 2017. PMID: 28715368 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous