Ultrasensitive quantification of serum vitamin D metabolites using selective solid-phase extraction coupled to microflow liquid chromatography and isotope-dilution mass spectrometry
- PMID: 20151683
- DOI: 10.1021/ac902869y
Ultrasensitive quantification of serum vitamin D metabolites using selective solid-phase extraction coupled to microflow liquid chromatography and isotope-dilution mass spectrometry
Abstract
The capacity for quantification of active metabolites of vitamin D (VitD) is highly valuable to evaluate the risks and therapies for numerous diseases such as multiple sclerosis. However, the extremely low circulating levels and poor detectability of some dihydroxyl metabolites such as the 1alpha,25-dihydroxy-VitD(3) constitute a daunting challenge. Based on the combination of a selective solid-phase extraction (SPE) and a microflow liquid chromatography tandem mass spectrometry (microLC-MS/MS), we developed an ultrasensitive method for the robust, selective, and accurate quantification of four key VitD metabolites, including 25-hydroxy-VitD(2), 25-hydroxy-VitD(3), 24(R),25-dihydroxy-VitD(3), and 1alpha,25-dihydroxy-VitD(3), in serum samples. A one-step derivatization was employed to improve the ionization efficiency of the metabolites. The SPE procedure was optimized so that the analytes were selectively extracted from serum, while the sample matrix was substantially simplified. By eliminating majority of undesirable compounds from the matrix, the selective SPE enabled a high sample loading volume on the microLC column without causing overcapacity of the microLC column and thus helped to achieve ultralow detect limits in serum. An on-column sample focusing approach was employed to prevent band-broadening, and a sufficient microLC separation was achieved to eliminate endogenous interferences and to minimize ion suppression effect. Detect limits of the four metabolites ranged from 0.5-1 pg/mL, and the linearity was excellent for all compounds. The method showed high quantitative accuracy (error < 13.8%) and precision (CV < 14.1%). For 1alpha,25-dihydroxy-VitD(3), a lower limit of quantification (LLOQ) of 5 pg/mL was validated. This high level of sensitivity, for the first time, enabled the robust and consistent LC/MS/MS-based analysis of the four metabolites in a large-scale clinical investigation. Serum samples from 281 multiple sclerosis patients and 22 healthy subjects were analyzed, and it was discovered that the levels of both 24(R),25-dihydroxy-VitD(3) and 1alpha,25-dihydroxy-VitD(3) were significantly lower in patients than healthy subjects (P < 0.05). This novel observation may imply that the incidence of multiple sclerosis is inversely associated with the levels of the two metabolites. Moreover, the method was highly robust and reproducible as evaluated extensively in the clinical analysis; therefore, it could serve as a more selective and accurate alternative to immunoassay for large-scale clinical studies.
Similar articles
-
Ultra-sensitive quantification of corticosteroids in plasma samples using selective solid-phase extraction and reversed-phase capillary high-performance liquid chromatography/tandem mass spectrometry.Anal Chem. 2007 May 15;79(10):3786-93. doi: 10.1021/ac062184r. Epub 2007 Apr 6. Anal Chem. 2007. PMID: 17411010
-
Automated method for targeting analysis of prostanoids in human serum by on-line solid-phase extraction and liquid chromatography-mass spectrometry in selected reaction monitoring.J Chromatogr A. 2011 May 20;1218(20):2848-55. doi: 10.1016/j.chroma.2011.03.049. Epub 2011 Mar 27. J Chromatogr A. 2011. PMID: 21481401
-
A simple automated solid-phase extraction procedure for measurement of 25-hydroxyvitamin D3 and D2 by liquid chromatography-tandem mass spectrometry.Ann Clin Biochem. 2009 May;46(Pt 3):226-30. doi: 10.1258/acb.2009.008206. Ann Clin Biochem. 2009. PMID: 19389886
-
Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: a review.J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Jun 15;878(20):1654-61. doi: 10.1016/j.jchromb.2009.11.026. Epub 2009 Nov 18. J Chromatogr B Analyt Technol Biomed Life Sci. 2010. PMID: 19962356 Review.
-
Overview of extraction methods for analysis of vitamin D and its metabolites in biological samples.Bioanalysis. 2011 Sep;3(17):1987-2002. doi: 10.4155/bio.11.195. Bioanalysis. 2011. PMID: 21899507 Review.
Cited by
-
Automation der Bestimmung von Vitamin D in Serum und Plasma.Biospektrum (Heidelb). 2021;27(6):660-662. doi: 10.1007/s12268-021-1649-6. Epub 2021 Oct 9. Biospektrum (Heidelb). 2021. PMID: 34658540 Free PMC article. Review. German.
-
An ultra-sensitive and high-throughput trapping-micro-LC-MS method for quantification of circulating vitamin D metabolites and application in multiple sclerosis patients.Sci Rep. 2024 Mar 6;14(1):5545. doi: 10.1038/s41598-024-55939-0. Sci Rep. 2024. PMID: 38448553 Free PMC article.
-
A systematic approach to development of analytical scale and microflow-based liquid chromatography coupled to mass spectrometry metabolomics methods to support drug discovery and development.J Chromatogr A. 2021 Apr 12;1642:462047. doi: 10.1016/j.chroma.2021.462047. Epub 2021 Mar 9. J Chromatogr A. 2021. PMID: 33744605 Free PMC article.
-
Quantification of vitamin D and 25-hydroxyvitamin D in soft tissues by liquid chromatography-tandem mass spectrometry.J Chromatogr B Analyt Technol Biomed Life Sci. 2013 Aug 1;932:6-11. doi: 10.1016/j.jchromb.2013.05.029. Epub 2013 Jun 6. J Chromatogr B Analyt Technol Biomed Life Sci. 2013. PMID: 23811497 Free PMC article.
-
The When, What & How of Measuring Vitamin D Metabolism in Clinical Medicine.Nutrients. 2018 Apr 13;10(4):482. doi: 10.3390/nu10040482. Nutrients. 2018. PMID: 29652819 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical