An aptamer-based assay for thrombin via structure switch based on gold nanoparticles and magnetic nanoparticles
- PMID: 20152425
- DOI: 10.1016/j.talanta.2009.10.036
An aptamer-based assay for thrombin via structure switch based on gold nanoparticles and magnetic nanoparticles
Abstract
An aptamer-based assay for thrombin with high specificity and sensitivity was presented. In the protocol, the aptamer for thrombin was immobilized on magnetic nanoparticle, and its complementary oligonucleotide was labeled with gold nanoparticles, then the aptamer was hybridized with the complementary oligonucleotide to form the duplex structure as a probe, this probe could be used for the specific recognition for thrombin. In the presence of thrombin, the aptamer prefer to form the G-quarter structure with thrombin, resulting in the dissociation of the duplex of the probe and the release of the gold labeled oligonucleotide. Upon this, we were able to detect thrombin through the detection of the electrochemical signal of gold nanoparticles. The strategy combines with the high specificity of aptamer and the excellent characteristics of nanoparticles. This assay is simple, rapid, sensitive and highly specific, it does not require labeling of thrombin, and it could be applied to detect thrombin in complex real sample. The method shows great potential in other protein analysis and in disease diagnosis.
Copyright (c) 2009 Elsevier B.V. All rights reserved.
Similar articles
-
Aptamer-linked assay for thrombin using gold nanoparticle amplification and inductively coupled plasma-mass spectrometry detection.Anal Chem. 2009 Sep 1;81(17):7484-9. doi: 10.1021/ac900961y. Anal Chem. 2009. PMID: 19670869
-
A new amplification strategy for ultrasensitive electrochemical aptasensor with network-like thiocyanuric acid/gold nanoparticles.Biosens Bioelectron. 2007 Oct 31;23(3):341-7. doi: 10.1016/j.bios.2007.04.015. Epub 2007 May 3. Biosens Bioelectron. 2007. PMID: 17583489
-
Ultrasensitive electrochemical aptasensor for thrombin based on the amplification of aptamer-AuNPs-HRP conjugates.Biosens Bioelectron. 2011 Jan 15;26(5):2297-303. doi: 10.1016/j.bios.2010.09.056. Epub 2010 Oct 8. Biosens Bioelectron. 2011. PMID: 21030239
-
Aptamer-conjugated gold nanoparticles for bioanalysis.Nanomedicine (Lond). 2013 Jun;8(6):983-93. doi: 10.2217/nnm.13.80. Nanomedicine (Lond). 2013. PMID: 23730697 Review.
-
Homogeneous assays using aptamers.Analyst. 2011 Jan 21;136(2):257-74. doi: 10.1039/c0an00281j. Epub 2010 Oct 14. Analyst. 2011. PMID: 20949139 Review.
Cited by
-
Sensitivity and selectivity on aptamer-based assay: the determination of tetracycline residue in bovine milk.ScientificWorldJournal. 2012;2012:159456. doi: 10.1100/2012/159456. Epub 2012 Apr 1. ScientificWorldJournal. 2012. PMID: 22547977 Free PMC article.
-
Recent advances and achievements in nanomaterial-based, and structure switchable aptasensing platforms for ochratoxin A detection.Sensors (Basel). 2013 Nov 6;13(11):15187-208. doi: 10.3390/s131115187. Sensors (Basel). 2013. PMID: 24201319 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources