. 2010 Feb;58(2):68-77.
doi: 10.1007/s11748-009-0536-8. Epub 2010 Feb 13.

New device for intraoperative graft assessment: HyperEye charge-coupled device camera system

Affiliations

New device for intraoperative graft assessment: HyperEye charge-coupled device camera system

Takemi Handa et al. Gen Thorac Cardiovasc Surg. 2010 Feb.

Abstract

Purpose: Our institution developed a new color chargecoupled device (CCD) camera system (HyperEye system) for intraoperative indocyanine green (ICG) angiography. The device consists of a combination of custommade optical filters and an ultra-high-sensitive CCD image sensor with non-Bayer color filter array (i.e., HyperEye technology), which can detect simultaneously color and near-infrared (NIR) rays from 380 to 1200 nm. Here, we demonstrate intraoperative graft assessment using the HyperEye system.

Methods: We investigated the intraoperative graft patency using both the HyperEye system and transittime flowmetry (TFM) in 51 patients between April 2007 and April 2009 while ICG dye was injected through a central venous catheter. Each patient signed a consent form before the surgery.

Results: We obtained intraoperative graft flows and images in 189 anastomoses of 153 grafts. Both the HyperEye system and TFM indicated the patency of the grafts in 129 grafts. Both the HyperEye system and TFM detected the abnormality of the graft in seven grafts. For the competitive flows, the HyperEye system captured to-and-fro flow fluorescence and TFM detected the retrograde waveform in 16 grafts. On the other hand, although TFM indicated the patency of the graft, the HyperEye system suspected nonoccluded graft failure in seven grafts. In contrast, although TFM detected a mean flow of <10 ml/min, the HyperEye system captured the patent perfusion fluorescence in four grafts.

Conclusion: The HyperEye system can visualize any structural and functional failures. Our findings suggest that this device could become a useful tool for intraoperative graft assessment.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Thorac Cardiovasc Surg. 2006 Sep;132(3):585-94 - PubMed
    1. Chest. 2004 Feb;125(2):418-24 - PubMed
    1. Ann Thorac Surg. 2007 Jun;83(6):2251-7 - PubMed
    1. Eur J Cardiothorac Surg. 1997 Jun;11(6):1086-92 - PubMed
    1. J Surg Res. 1997 Aug;71(2):172-8 - PubMed

Publication types

MeSH terms

LinkOut - more resources