Accuracy of oscillometric devices in children and adults
- PMID: 20156034
- DOI: 10.3109/08037051003606439
Accuracy of oscillometric devices in children and adults
Abstract
Clinical validation of blood pressure oscillometric devices are almost exclusively conducted in adults. Because oscillometric devices are used in children, it is critical to assess their accuracy also in this population. We compared blood pressure readings using an oscillometric automated device (Dinamap XL, model CR9340) with readings obtained with the mercury auscultatory method in children and adults. Blood pressure was measured in 30 children (15 boys and 15 girls; 9.5+/-1.0 years old) and their parents (25 mothers and 15 fathers; 41.0+/-5.0 years old). In children, mean difference (+/-SD) in systolic blood pressure (DeltaBP) readings (oscillometric-auscultatory) was +0.6+/-4.7 mmHg (range: -10 to +11); mean diastolic DeltaBP was 21.3+/-7.5 mmHg (range: -18 to +19) and decreased with increasing diastolic BP. In adults, mean systolic DeltaBP was +0.4+/-5.2 mmHg (range: -12 to +15) and mean diastolic DeltaBP was -5.2+/-6.0 mmHg (range: -25 to +8) (p<0.001). While the device was not accurate enough to be recommended, our study also shows that the accuracy of blood pressure oscillometric devices can differ between children and adults. Clinical accuracy of oscillometric devices should be tested in the specific populations in whom blood pressure is measured.
Similar articles
-
Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanometer in children.Blood Press Monit. 2006 Oct;11(5):281-91. doi: 10.1097/01.mbp.0000209082.09623.b4. Blood Press Monit. 2006. PMID: 16932037 Clinical Trial.
-
Validation of TM-2655 oscillometric device for blood pressure measurement.Blood Press Monit. 2006 Apr;11(2):87-90. doi: 10.1097/01.mbp.0000200484.49540.12. Blood Press Monit. 2006. PMID: 16534410
-
In vitro and in vivo evaluation of an oscillometric device for monitoring blood pressure in dialysis patients.Nephrol Dial Transplant. 2007 Oct;22(10):2950-61. doi: 10.1093/ndt/gfm288. Epub 2007 Jun 7. Nephrol Dial Transplant. 2007. PMID: 17556423
-
Home blood pressure measurement with oscillometric upper-arm devices.Neth J Med. 2003 Oct;61(10):307-12. Neth J Med. 2003. PMID: 14708907 Review.
-
Can an automatic oscillometric device replace a mercury sphygmomanometer on blood pressure measurement? a systematic review and meta-analysis.Blood Press Monit. 2019 Dec;24(6):265-276. doi: 10.1097/MBP.0000000000000412. Blood Press Monit. 2019. PMID: 31658107
Cited by
-
Automated oscillometric blood pressure measurement in children.J Clin Hypertens (Greenwich). 2014 Jun;16(6):468. doi: 10.1111/jch.12315. Epub 2014 Apr 11. J Clin Hypertens (Greenwich). 2014. PMID: 24720677 Free PMC article. No abstract available.
-
Comparison of Blood Pressure Measurements by Currently Available Multiparameter Monitors and Mercury Column Sphygmomanometer in Patients Admitted in Pediatric Intensive Care Unit.Indian J Crit Care Med. 2023 Mar;27(3):212-221. doi: 10.5005/jp-journals-10071-24424. Indian J Crit Care Med. 2023. PMID: 36960118 Free PMC article.
-
User-friendly tools to identify elevated blood pressure in children.Paediatr Child Health. 2013 Feb;18(2):63-4. doi: 10.1093/pch/18.2.63. Paediatr Child Health. 2013. PMID: 24421657 Free PMC article. No abstract available.
-
Validation of the RisingSun RS-651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060-2:2013 Standard.J Clin Hypertens (Greenwich). 2016 Dec;18(12):1279-1283. doi: 10.1111/jch.12859. Epub 2016 Jun 7. J Clin Hypertens (Greenwich). 2016. PMID: 27271472 Free PMC article.
-
Assessing the consequences of gestational diabetes mellitus on offspring's cardiovascular health: MySweetHeart Cohort study protocol, Switzerland.BMJ Open. 2017 Nov 14;7(11):e016972. doi: 10.1136/bmjopen-2017-016972. BMJ Open. 2017. PMID: 29138200 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources