Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer device
- PMID: 20156932
- PMCID: PMC4627487
- DOI: 10.1177/1078155210361431
Reduction in surface contamination with antineoplastic drugs in 22 hospital pharmacies in the US following implementation of a closed-system drug transfer device
Abstract
Purpose: Surface contamination with the antineoplastic drugs cyclophosphamide, ifosfamide, and 5-fluorouracil was compared in 22 US hospital pharmacies following preparation with standard drug preparation techniques or the PhaSeal® closed-system drug transfer device (CSTD).
Methods: Wipe samples were taken from biological safety cabinet (BSC) surfaces, BSC airfoils, floors in front of BSCs, and counters and analyzed for contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil. Contamination was reassessed several months after the implementation of the CSTD. Surface contamination (ng/cm(2)) was compared between the two techniques and evaluated with the Signed Rank Test.
Results: Using the CSTD compared to the standard preparation techniques, a significant reduction in levels of contamination was observed for all drugs (cyclophosphamide: p < 0.0001; ifosfamide: p < 0.001; 5-fluorouracil: p < 0.01). Median values for surface contamination with cyclophosphamide, ifosfamide, and 5-fluorouracil were reduced by 95%, 90%, and 65%, respectively.
Conclusions: Use of the CSTD significantly reduces surface contamination when preparing cyclophosphamide, ifosfamide, and 5-fluorouracil as compared to standard drug preparation techniques.
References
-
- Sessink PJM, Bos RP. Drugs hazardous to healthcare workers. Drug Safety. 1999;20:347–359. - PubMed
-
- Acampora A, Castiglia L, Miraglia N, et al. A case study: Surface contamination of cyclophosphamide due to working practices and cleaning procedures in two Italian hospitals. Ann Occup Hyg. 2005;49:611–618. - PubMed
-
- Connor TH, Anderson RW, Sessink PJM, et al. Surface contamination with antineoplastic agents in six cancer treatment centers in Canada and the United States. Am J Health-Syst Pharm. 1999;56:1427–1432. - PubMed
-
- Connor TH, Anderson RW, Sessink PJ, et al. Effectiveness of a closed-system device in containing surface contamination with cyclophosphamide and ifosfamide in an i.v. admixture area. Am J Health-Syst Pharm. 2002;59:68–72. - PubMed
-
- Crauste-Manciet S, Sessink PJM, Ferrari S, et al. Environmental contamination with cytotoxic drugs in healthcare using positive air pressure isolators. Ann Occup Hyg. 2005;49:619–628. - PubMed