Cardiac tamponade and successful pericardiocentesis in an extremely low birth weight neonate with percutaneously inserted central venous line: a case report
- PMID: 20157646
- PMCID: PMC2821304
- DOI: 10.1186/1757-1626-3-15
Cardiac tamponade and successful pericardiocentesis in an extremely low birth weight neonate with percutaneously inserted central venous line: a case report
Abstract
Background: Pericardial effusion and cardiac tamponade are rare but life-threatening complications of percutaneosuly inserted central line (PICL) use in extremely low birth weight (ELBW) neonates, with an incidence reported between 0.07% and 2% of PICLs placement. Timely diagnosis and pericardiocentesis has been proven to be life-saving.
Case presentation: The patient was a 620 g birth weight neonate who presented with sudden cardiac instability 18 days after the insertion of a PICL and in spite of a presumed satisfactory position of the catheter tip. The transthoracic echocardiography demonstrated severe pericardial effusion with evidence of cardiac tamponade. Successful urgent subxiphoid pericardiocentesis was performed; totally 2 ml of whitish fluid was collected, which resulted consistent to the composition of the hyperosmolar TPN solution infused.
Conclusion: Cardiac tamponade should be considered in any newborn with a peripherally inserted central catheter who presents with cardiorespiratory instability (bradycardia, cyanosis and metabolic acidosis), even when lines are believed to be placed correctly.