Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Feb;28(2):195-202.
doi: 10.1016/j.ajem.2009.10.006.

Outcomes from low versus high-flow cardiopulmonary resuscitation in a swine model of cardiac arrest

Affiliations

Outcomes from low versus high-flow cardiopulmonary resuscitation in a swine model of cardiac arrest

Henry R Halperin et al. Am J Emerg Med. 2010 Feb.

Abstract

Background: Return of spontaneous circulation (ROSC) is improved by greater vital organ blood flow during cardiopulmonary resuscitation (CPR). We tested the hypothesis that myocardial flow above the threshold needed for ROSC may be associated with greater vital organ injury and worse outcome.

Methods: Aortic and right atrial pressures were measured with micromanometers in 27 swine. After 10 minutes of untreated ventricular fibrillation, chest compression was performed with an automatic, load-distributing band. Animals were randomly assigned to receive flows just sufficient for ROSC (low flow: target coronary perfusion pressure = 12 mm Hg) or well above the minimally effective level (high flow: coronary perfusion pressure = 30 mm Hg). Myocardial flow was measured with microspheres, defibrillation was performed after 3.5 minutes of CPR, and ejection fraction was measured with echocardiography.

Results: Return of spontaneous circulation was achieved by 9 of 9 animals in the high-flow group and 15 of 18 in the low-flow group. All animals in the high-flow group defibrillated initially into a perfusing rhythm, whereas 12 of 15 animals achieving ROSC in the low-flow group defibrillated initially into pulseless electrical activity (P < .05, Fisher exact test). Compared with animals in the low-flow group, animals in the high-flow group had shorter resuscitation times, higher mean aortic pressures at ROSC, and higher ejection fractions at 2 hours post-ROSC (all P < .05).

Conclusion: High-flow CPR significantly improved arrest hemodynamics, rates of ROSC, and post-ROSC indicators of myocardial status, all indicating less injury with higher flows. No evidence of organ injury from vital organ blood flow substantially above the threshold for ROSC was found.

PubMed Disclaimer

Similar articles

Cited by

Publication types