Outcomes from low versus high-flow cardiopulmonary resuscitation in a swine model of cardiac arrest
- PMID: 20159390
- DOI: 10.1016/j.ajem.2009.10.006
Outcomes from low versus high-flow cardiopulmonary resuscitation in a swine model of cardiac arrest
Abstract
Background: Return of spontaneous circulation (ROSC) is improved by greater vital organ blood flow during cardiopulmonary resuscitation (CPR). We tested the hypothesis that myocardial flow above the threshold needed for ROSC may be associated with greater vital organ injury and worse outcome.
Methods: Aortic and right atrial pressures were measured with micromanometers in 27 swine. After 10 minutes of untreated ventricular fibrillation, chest compression was performed with an automatic, load-distributing band. Animals were randomly assigned to receive flows just sufficient for ROSC (low flow: target coronary perfusion pressure = 12 mm Hg) or well above the minimally effective level (high flow: coronary perfusion pressure = 30 mm Hg). Myocardial flow was measured with microspheres, defibrillation was performed after 3.5 minutes of CPR, and ejection fraction was measured with echocardiography.
Results: Return of spontaneous circulation was achieved by 9 of 9 animals in the high-flow group and 15 of 18 in the low-flow group. All animals in the high-flow group defibrillated initially into a perfusing rhythm, whereas 12 of 15 animals achieving ROSC in the low-flow group defibrillated initially into pulseless electrical activity (P < .05, Fisher exact test). Compared with animals in the low-flow group, animals in the high-flow group had shorter resuscitation times, higher mean aortic pressures at ROSC, and higher ejection fractions at 2 hours post-ROSC (all P < .05).
Conclusion: High-flow CPR significantly improved arrest hemodynamics, rates of ROSC, and post-ROSC indicators of myocardial status, all indicating less injury with higher flows. No evidence of organ injury from vital organ blood flow substantially above the threshold for ROSC was found.
Copyright 2010 Elsevier Inc. All rights reserved.
Similar articles
-
Cardiopulmonary resuscitation with a novel chest compression device in a porcine model of cardiac arrest: improved hemodynamics and mechanisms.J Am Coll Cardiol. 2004 Dec 7;44(11):2214-20. doi: 10.1016/j.jacc.2004.08.061. J Am Coll Cardiol. 2004. PMID: 15582320
-
A new device producing manual sternal compression with thoracic constraint for cardiopulmonary resuscitation.Resuscitation. 2006 May;69(2):295-301. doi: 10.1016/j.resuscitation.2005.07.025. Epub 2006 Feb 2. Resuscitation. 2006. PMID: 16457933
-
Post-resuscitation reperfusion injury: comparison of periodic Gz acceleration versus Thumper CPR.Resuscitation. 2006 Sep;70(3):454-62. doi: 10.1016/j.resuscitation.2005.12.016. Epub 2006 Jul 10. Resuscitation. 2006. PMID: 16828959
-
Application of impedance threshold devices during cardiopulmonary cerebral resuscitation.J Vet Emerg Crit Care (San Antonio). 2011 Jun;21(3):187-92. doi: 10.1111/j.1476-4431.2011.00640.x. Epub 2011 May 5. J Vet Emerg Crit Care (San Antonio). 2011. PMID: 21631704 Review.
-
Cardiopulmonary resuscitation with a hydraulic-pneumatic band.Crit Care Med. 2000 Nov;28(11 Suppl):N203-6. doi: 10.1097/00003246-200011001-00008. Crit Care Med. 2000. PMID: 11098947 Review.
Cited by
-
Coronary versus carotid blood flow and coronary perfusion pressure in a pig model of prolonged cardiac arrest treated by different modes of venoarterial ECMO and intraaortic balloon counterpulsation.Crit Care. 2012 Dec 12;16(2):R50. doi: 10.1186/cc11254. Crit Care. 2012. PMID: 22424292 Free PMC article.
-
Controlled progressive elevation rather than an optimal angle maximizes cerebral perfusion pressure during head up CPR in a swine model of cardiac arrest.Resuscitation. 2020 May;150:23-28. doi: 10.1016/j.resuscitation.2020.02.023. Epub 2020 Feb 27. Resuscitation. 2020. PMID: 32114071 Free PMC article.
-
Influence of Chest Compressions on Circulation during the Peri-Cardiac Arrest Period in Porcine Models.PLoS One. 2016 May 11;11(5):e0155212. doi: 10.1371/journal.pone.0155212. eCollection 2016. PLoS One. 2016. PMID: 27168071 Free PMC article.
-
Effects of Polyethylene Glycol-20k on Coronary Perfusion Pressure and Postresuscitation Myocardial and Cerebral Function in a Rat Model of Cardiac Arrest.J Am Heart Assoc. 2020 Feb 4;9(3):e014232. doi: 10.1161/JAHA.119.014232. Epub 2020 Jan 30. J Am Heart Assoc. 2020. PMID: 32013701 Free PMC article.
-
Hemodynamic directed CPR improves short-term survival from asphyxia-associated cardiac arrest.Resuscitation. 2013 May;84(5):696-701. doi: 10.1016/j.resuscitation.2012.10.023. Epub 2012 Nov 7. Resuscitation. 2013. PMID: 23142199 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical