Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2010 Mar;31(6):659-66.
doi: 10.1093/eurheartj/ehq013. Epub 2010 Feb 16.

Circulating microRNA: a novel potential biomarker for early diagnosis of acute myocardial infarction in humans

Affiliations

Circulating microRNA: a novel potential biomarker for early diagnosis of acute myocardial infarction in humans

Guo-Kun Wang et al. Eur Heart J. 2010 Mar.

Abstract

Aims: microRNA (miRNA) is reported to be present in the blood of humans and has been increasingly suggested as a biomarker for diseases. We aim to determine the potential of cardiac-specific miRNAs in circulation to serve as biomarkers for acute myocardial infarction (AMI).

Methods and results: By verifying their tissue expression patterns with real-time polymerase chain reaction (PCR) analysis, muscle-enriched miRNAs (miR-1, miR-133a, and miR-499) and cardiac-specific miR-208a were selected as candidates for this study. With miRNA microarray and real-time PCR analyses, miR-1, miR-133a, and miR-499 were present with very low abundance, and miR-208a was absent in the plasma from healthy people. In the AMI rats, the plasma levels of these miRNAs were significantly increased. Especially, miR-208a in plasma was undetected at 0 h, but was significantly increased to a detectable level as early as 1 h after coronary artery occlusion. Further evaluation of the miRNA levels in plasma from AMI patients (n = 33) demonstrated that all four miRNA levels were substantially higher than those from healthy people (n = 30, P < 0.01), patients with non-AMI coronary heart disease (n = 16, P < 0.01), or patients with other cardiovascular diseases (n = 17, P < 0.01). Notably, miR-208a remained undetectable in non-AMI patients, but was easily detected in 90.9% AMI patients and in 100% AMI patients within 4 h of the onset of symptoms. By receiver operating characteristic curve analysis, among the four miRNAs investigated, miR-208a revealed the higher sensitivity and specificity for diagnosing AMI.

Conclusion: Elevated cardiac-specific miR-208a in plasma may be a novel biomarker for early detection of myocardial injury in humans.

PubMed Disclaimer

Similar articles

Cited by

Publication types