Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2012 Mar;90(2):184-7.
doi: 10.1111/j.1755-3768.2009.01849.x. Epub 2010 Feb 16.

Comparison of bimanual and micro-coaxial phacoemulsification with torsional ultrasound

Affiliations
Free article
Randomized Controlled Trial

Comparison of bimanual and micro-coaxial phacoemulsification with torsional ultrasound

Yujuan Wang et al. Acta Ophthalmol. 2012 Mar.
Free article

Abstract

Purpose: To evaluate the efficacy and postoperative outcomes of bimanual and micro-coaxial phacoemulsification with torsional ultrasound.

Methods: In this prospective randomized series, eyes with age-related cataract were randomly divided into bimanual phacoemulsification and micro-coaxial phacoemulsification groups. Data included preoperative and postoperative corrected distance visual acuity (CDVA), central/temporal corneal thickness, endothelial cell density and intraoperative ultrasound time, cumulative dissipated energy and balanced salt solution volume.

Results: The study evaluated 89 patients (89 eyes). When compared between micro-coaxial and bimanual phaco groups, ultrasound time (57 ± 24 second versus 85 ± 40 second, p < 0.01), cumulative dissipated energy (10 ± 7 versus 14 ± 7, p = 0.01) and balanced salt solution volume (55 ± 19 ml l versus 75 ± 20 ml, p < 0.01) were significantly lower in micro-coaxial phaco group. At 1 day, there were no statistically significant differences in CDVA (p = 0.68) or central corneal thickness (p = 0.48) between two groups; temporal corneal thickness was statistically significantly thicker in bimanual phaco group (1247 ± 123 μm) than that in micro-coaxial phaco group (1108 ± 131 μm, p = 0.01). There were no statistically significant differences in CDVA, central/temporal corneal thickness, or endothelial cell density between two groups 30 days postoperatively (all p values >0.05).

Conclusion: With rapid visual rehabilitation and comparable endothelial cell loss, both bimanual and micro-coaxial phacoemulsification procedures with torsional ultrasound are efficient for moderate nuclear cataract extraction.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources